background image

Interface Wiring Diagram 

(Oriented the same as the Watchman install)

 

Wire 

main power

 from the transformer to the power connector on the

circuit board.

Connect gate trigger wires from the 

Normally Open

 (NO)

 and 

Common

 (C)

to the free-exit or exit terminals on the gate operator.

Connect the gate status wires on the 6-pin connector on the main relay

and input plug to the magnetic switch or a 

Dry Contact

, Normally Closed (NC)

relay on the gate operator.

If using an optional 26-bit reader (ex., keypad, card reader, RFID, or

clicker), wire the device to the 

Wiegand connection

 on the interface circuit

board.

Use 

Camera Guide

 if adding optional external camera.

Test/activate using the test credentials on the 

Activation & Test Process

document.

6-Wire Installation Instructions

Important Item 

WXL 

18 gauge stranded - up to 25 ft 

16 gauge stranded - up to 50 ft 

12 gauge stranded - up to 60 ft 

Recommended Wire Guide