37
Web Setting
OSD
- Font Size : Normal / Big
- Date Enable : display date
- Time Enable : display time
- Channel Enable : display channel name
- X Axis: Input a point on the coordinate
- Y Axis: Input a point on the coordinate
Logo
- This means the image that is displayed on OSD of the transferred image.
- First, upload the logo image on “Expert/Firmware Update/OSD logo upload” (BMP file)
- Enable: Check the box to display the image
- X Axis: Input a point on the coordinate
- Y Axis: Input a point on the coordinate
► OSD on image
Date / Time / Channel Name
OSD logo
38
Web Setting
• Expert > PTZ / RS232
(under development)
• Expert > PTZ / RS232
- CamPilot MR330 does not support PTZ(RS485) function.
- This page will be deleted on the next firmware release.
Channel 1
- Channel Name : the channel name of OSD
- Channel Model (PTZ model)
: Select a model of the connected PTZ camera or receiver
- Channel ID (Rx Address)
: the Rx address of the connected PTZ camera or receiver
- Baud rate / Data bits / Parity / Stop bits
: select the value properly by the receiver type
RS232
- Baud rate / Data bits / Parity / Stop bits
: select the value properly by the receiver type
39
Web Setting
• Expert > Local Storage (Optional)
- Local Storage function is automatically mounted when inserted into the SD / SDHC card
slot.
Status
- Display the total space, used space and free space of SD / SDHC Card.
Record Setting
- Mode : Select a record type (OFF / Full Recording / Event Recording)
- Select a video stream of CamPilot MR330 (1st / 2nd / 3rd Stream)
- Select a overwrite setting of the local storage (ON/OFF)
File list
- Recorded file is produced every 10MB.
- User can download and delete a recorded file.
40
Web Setting
•
Expert > Port
Web
- Web Port: Default is 80
FTP
- FTP Port: Default is 21