User manual

MM601 / MM600P1

Quick Guide

Register as a customer and create an account for the Celsiview cloud service

At the moment the Celsiview cloud service version two can be tested, it can be accessed by click-
ing on the ”Celsiview 2 Beta” button on celsiview.se. The instructions below are based on Celsiview 
2.

Click on the ”Create new account” button. Fill in all the information needed to create the account. 
A verification email will then be sent to the email address provided in the registration process. 
Click on the link in the email to verify the account. If you do not receive an email, please check the 
spam mail. Once the account is verified, a page will appear with a link to the login page.

Adding the sensor to your sensor register

Go to the Celsiview 2 login page by clicking on ”Celsiview 2 Beta” on celsiview.se and log in. Select 
” Sensor ” in the menu and then ” Add new sensor ”. Now scan a sensor or enter the data manually 
(S/N + control code written on the sensor). After the sensor data is displayed, click on ”Add this 
sensor”. The cost of the sensor is now presented. Accept by adding the sensor to the shopping bas-
ket. Now scan the remaining sensors in the same way before proceeding to checkout.

Click on the shopping basket and view the contents. A summary of the costs is now displayed. Se-
lect or create an invoice recipient. The invoice recipient should contain all the information needed 
to be accepted by your finance department. The references, cost centre, etc. will appear on your 
invoice. Click on ”Complete transaction” to activate the sensor. 

Start and activate the sensor(s)

Connect the separate measuring node MM600P1 via the connector on the cable from MM601. 
The cable can be plugged into any of the two connector slots on the MM600P1 node. In the free 
connector slot, an additional MM600P1 can be connected via a bus cable (purchased separately). 
Up to 8 nodes can be connected to one MM601 master sensor. On the round switch you set which 
node in the order you connected (1 to 8). 

Hold the grey sensor in both hands, place your right and left thumbs on top of the °celsicom logo 
on the top of the sensor. Now slide the lid upwards/forwards to open it.

Insert 2 alkaline AA/LR6 batteries (1.5V) into the battery holder. The sensor will now beep to indi-
cate that it is booting up and the orange LED will light up. Both orange and green LEDs will light 
up shortly afterwards in a constant light while the sensor is searching for a mobile connection. 
The connection to the mobile network may take several minutes.

Summary of Contents for MM601

Page 1: ...n the same way before proceeding to checkout Click on the shopping basket and view the contents A summary of the costs is now displayed Se lect or create an invoice recipient The invoice recipient should contain all the information needed to be accepted by your finance department The references cost centre etc will appear on your invoice Click on Complete transaction to activate the sensor Start a...

Page 2: ...or location list click on the plus sign and enter a name prefix for the readings e g Moisture con tent sensor Press OK The locations are now created and can be found under the menu item Locations If only a single MM600P1 measurement node is to be used click on the symbol with a down arrow All 8 channels of the sensor will be opened Now click on the map pin location on the channel 1 to 8 where a me...

Page 3: ...mation Stainless steel screws work well as measuring points in the measurement object wooden structure Pins nails may drop out of the material as it dries Avoid interference with the measurement signal by following these points The MM600P1 measuring node should be placed at least 1 meter away from electrical equipment or cables The bus cable between the MM601 and the MM600P1 should not pass close ...

Page 4: ...onnection NB IoT LTE Cat NB1 B20 Power 23 dBm Batteries 2 x AA LR6 1 5V not included Battery time Depending on the transmission interval Example at 20 C good signal quality measurement every 3 hours and transmission every 3 hours 12 months Measurement and transmissi on interval Adjustable by users via the Celsiview cloud service Memory 200 measurements Size MM601 enclosure 78 w x 114 h x 30 d mm M...

Reviews: