My business
In the ”My business” menu, sites can be structured into different groups/folders. Right-click on ”Groups
and locations” to create a group/folder. Then drag and drop the measurement locations you want into
any group.
A group or location can also be shared with another person by right-clicking on the location or group
and selecting ”Share”. Select ”Create new user”, enter the email address of the person to be assigned
to the site/group. Automatically, the username of that person will be set to the same as the email
address. Click on ”OK”. The new recipient now appears in the list of selectable recipients. Select the
rights the new user should have. Click on ”OK”. The new user will now receive an e-mail asking him to
choose a password. The new user can then log in with their details and will have access to what has
been distributed.
Add alarm recipients
Log in to the account. Click on the username in the top right corner. Select ”Alarm handling”. Add the
email addresses/SMS numbers where alerts should be sent. Test the alarm by clicking on the letter
symbol of the recipient to which the test should be sent. NOTE! Check that it arrives.
Other information
Stainless steel screws work well as measuring points in the measurement object (wooden structure).
Pins/nails may drop out of the material as it dries.
Avoid interference with the measurement signal by following these points:
•
The MM600P1 measuring node should be placed at least 1 meter away from electrical equipment
or cables
•
The bus cable between the MM601 and the MM600P1 should not pass close to the measuring point
•
The bus cable should be placed as far away from electrical cables/equipment as possible and
should not be parallel to other cables
•
The measuring cables are sensitive to ESD/static electricity. Take measures to protect them
•
A jagged/uneven waveform in a report indicates interference at the measurement point
The encoder should be mounted with the three half-rings on the cover facing upwards and the logo
facing downwards. If the sensor is to be mounted against a metal surface, magnetic mount 7040
0060 (or other non-metallic spacer) must be used to bring the sensor out at least 10 mm from the
mounting surface. Otherwise, the metal surface will interfere with the connection of the sensor and
the measurement data will have difficulty reaching our servers.
Support
All support is handled by our distributors. See celsicom.se for more information. User manuals and
other support material are available at support.celsicom.se.