Meter  Functions-  ms-PULSE  (Pulse  Width)  & 

ms- PERIOD (Period) 

Pulse  Width  is  the  length  of  time  an  actuator  is  energized.  For 

example,  fuel  injectors  are  activated  by  an  electronic  pulse  from 

the Engine Control Module (ECM). 

This pulse generates a magnetic field that pulls the injectors nozzle 

valve open.   

The pulse ends and the injector nozzle is closed.   

This  open  to  close  time  is  the  Pulse  Width  and  is  measured  in 

milliseconds( ms). 

 

The  most  common  automotive  application  for  measuring  pulse 

width is on fuel injectors.   

You  can  also  measure  the  pulse  width  of  the  fuel  mixture  control 

solenoid and the idle air control motor. 

 

This  exercise  shows  how  to  measure  Pulse  Width  on  Port  Fuel 

injectors. 

 

 

 

 

 

 

 

 

 

 

 

To measure pulse width (mS): 

Select the mS-Pulse function 

with the rotary switch . 

Press  the 

±

TRIG  button  for   

2  seconds  until  the  negative 
(-)  trigger  slope  is  displayed 
on  the  lower  left  side  of  the 
display. 

NOTE  :  The  applied  time  for 

most  fuel  injectors  is 
displayed 

on 

the 

negative (-) slope. 

Insert: 

Black lead in 

COM

 jack. 

Red lead in 

RPM-V-

Ω

  jack. 

Connect: 

Jumper  wires  between  the  fuel 
injector 

and 

the 

harness 

connector. 

Black  test  probe  to  a  good 
ground at the fuel injector or the 
negative (-) vehicle battery post. 

Red  test  probe  to  the  fuel 
injector  solenoid  driver  input  on 
the jumper cable. 

Start the engine. A pulse width in 
milliseconds should be read. 

If  reading  is  too  high  or 
unstable,,adjust  the  trigger  level 
by  pressing  the 

±

  TRIG  button 

for improved reading. 

 
 

 

 

 

 

 

Summary of Contents for DT-9995

Page 1: ...2 MAX MIN RS232 Button 12 Relative Button 12 Meter Functions Voltage V 14 Resistance 15 Diode Check 16 Audible Continuity 17 AC or DC Current A 18 Temperature 0 F 19 Frequency Hz 20 Dwell 21 Duty Cycl...

Page 2: ...airing vehicles Exceeding the limits of this meter is dangerous This will expose you to serious or possibly fatal injury Carefully read and understand the cautions and the specification limits of this...

Page 3: ...fuses To avoid possible injury or damage use only in circuits limited to 400mA or 20A for 30 seconds See also Fuse Replacement Safety Cont d IMPORTANT To maintain accuracy of the meter replace the di...

Page 4: ...5 6 Notes Getting Started his chapter will help you get started It describes the basic functions of the Meter...

Page 5: ...est lead is used to measure Amps Volts Ohms TEMP Hz RPM Cap mS and Dwell The Black test lead is used in the Common COM terminal for all tests Meter Basics Cont d Digital and Analog display AC DC Press...

Page 6: ...e between DC and AC in the voltage current measurements Range CYL Select The range is automatically selected by the meter You can also manually select a range or DWELL CYL range within a function by p...

Page 7: ...3 4 1V 2 2 1 V 1 0 8 V Data Hold Backlight The Data Hold Feature stores the last reading in memory Press the Data Hold button once to hold the present reading Press the Data Hold button again to exit...

Page 8: ...minal Red lead in V PRM terminal Touch the Black probe to ground or to the negative circuit Touch the Red probe to the circuit coming from the power source IMPORTANT Voltage must be measuring in paral...

Page 9: ...eter Functions Diode Check IMPORTANT Turn the power OFF to the test circuit Select the Diode Check function with the rotary switch Insert Black lead in COM terminal Red lead in V RPM terminal Touch th...

Page 10: ...rrent greater than 600 Volts AC or DC with respect to ground Do Not Exceed 30 seconds when measuring continuous current between 1A 20A Allow five minutes for cool down before continuing Select the 20A...

Page 11: ...erature probe connector into the K type thermocouple socket Touch the end of the temperature sensor to the area or surface of the object to be measured Temperature Sensor Temperature probe Meter Funct...

Page 12: ...stration Meter Functions Duty Cycle Select the Duty Cycle range with the rotary switch Insert Black lead in COM terminal Red lead in V RPM terminal Connect the Black test probe to ground Connect the R...

Page 13: ...This exercise shows how to measure Pulse Width on Port Fuel injectors To measure pulse width mS Select the mS Pulse function with the rotary switch Press the TRIG button for 2 seconds until the negat...

Page 14: ...N ALSO BE USED TO CORRECT AN UNSTABLE READING Maintenance Replacing The Battery WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery door 1...

Page 15: ...r the20A range 6 Put the fuse door back in place Insert the screw and tighten it securely WARNING To avoid electric shock do not operate your meter until the fuse door is in place and fastened securel...

Page 16: ...ond nominal Operating Environment 0 to 50 32 0 F to 122 0 F at 70 R H Storage Environment 20 to 60 4 F to 140 at 80 R H Temperature Coefficient 0 2 specified accuracy 18 or 28 Power Single standard 9...

Page 17: ...1 5 of rdg 3 dgts 40 00mA 10uA 400 0mA 100uA 4A 1mA 2 5 of rdg 5 dgts 20A 10mA Overload Protection 0 5A 250V and 20A 500V Fuse Maximum Input 400mA dc or 400mA ac rms on uA mA ranges 20A dc or ac rms...

Page 18: ...load protection 250V dc or ac rms Period Range Resolution Accuracy 2 0 20 0ms 0 1ms 3 of rdg 10 dgts Overload protection 250V dc or ac rms Pulse Width Range Resolution Accuracy 2 0 10 0ms 0 1ms 3 of r...

Page 19: ...ant to print out e g If you want to print the graph area from number 0 to 100 move the cursor to number 0 and click If you want to print the graph area from number 50 to 100 move the cursor to number...

Page 20: ...37 38 Note Please click Help on the PC interface for detailed instruction...

Reviews: