18
Ver. 05-2015
ENGLISH
Use and maintenance manual
Diagnostics
WARNING
T
he
INfoRmATIoN
IN
The
possIble Remedy
columN
RequIRes
WoRk
To
be
peRfoRmed
by
specIAlIsT
TechNIcIANs
oR
oTheR
AuThoR
-
Ised
people
Who
musT
AlWAys
WoRk
usING
The
p
eRsoNAl
p
RoTecTIve
e
quIpmeNT
INdIcATed
IN
The
INsTAllATIoN
mANuAl
. I
N
some
cAses
,
ThIs
WoRk
cAN
be
peRfoRmed
by
A
NoRmAl
opeRAToR
.
ERROR
CAUSE
POSSIBLE REMEDY
Black
The wheel balancer does not switch
on.
1. Check the machine is properly connected to the mains power
supply.
2. Check the fuses on the power board and replace if necessary.
3. Replace the CPU board.
Err. 1
No rotation signal.
1. Use the self-diagnostics function to check the encoder.
2. Replace the encoder.
3. Replace the CPU board.
Err. 2
Speed too low during detection.
During the unbalance measurement
revolutions, the wheel speed has
fallen to below 42 rpm.
1. Make sure that a vehicle wheel is mounted on the wheel balancer.
2. Use the self-diagnostics function to check the encoder.
3. Disconnect the piezo connectors from the board and do a spin
(if no error is detected, replace the piezo sensors).
4. Replace the CPU board.
Err. 3
Unbalance too high.
1. Check the wheel dimensions setting.
2. Check the detection unit connections.
3. Run the machine calibration function.
4. Mount a wheel with more or less known unbalance (less than
100 grams) and check the response of the machine.
5. Replace the CPU board.
Err. 4
Rotation in opposite direction.
1. Use the self-diagnostics function to check the encoder.
2. Check the encoder bearing/spring.
Err. 5
Guard open
The [START] pushbutton was pressed
without first closing the guard.
1. Reset the error.
2. Close the guard.
3. Verify the function of the protection switch.
4. Press the [START] button.
Err. 6
Spindle open (SE version)
The guard has been closed without
first closing the spindle
1. Reset the error
2. Close the spindle
3. Close the guard.
Err. 7
Err. 8
Err. 9
NOVRAM parameter read error
1. Switch off the machine and wait for at least ~ 1 min;
re-start the machine and check it works properly.
2. Repeat machine calibration.
3. Replace the CPU board.
Err. 11
Too high speed error.
The average spinning speed is more
than
240 rpm.
1. Check functioning of the phase encoder and, in particular, the reset
signal.
2. Replace the computer board.
Err.14
Err.15
Err.16
Err.17
Err.18
Err. 19
Unbalance measurement error.
1. Use the self-diagnostics function to check the encoder.
2. Check the detection unit connections.
3. Check the machine earthing connection.
4. Mount a wheel with more or less known unbalance (less than
100 grams) and check the response of the machine.
5. Replace the CPU board.
Err. 20
Wheel still. The wheel must remain
still for more than one second after
START.
1. Use the self-diagnostics function to check the encoder.
2. Check the connections on the power board.
3. Replace the CPU board.
Err. 21
Motor on for more than 15
seconds.
1. Use the self-diagnostics function to check the encoder.
2. Check the connections on the power board.
3. Replace the CPU board.