ENGLISH
Installation manual Ver. 05-2017
8
3.5.1 Removing the pallet
The machine is secured to a base pallet. Prepare an adequate area with level flooring and mark it off before lifting
the machine and positioning it on the ground.
To remove the machine from the pallet operate as follows:
▪
Remove the screws that lock the machine to the pallet
(figure on the side)
WARNING
manual handling and lifting of the machine must be carried out with the aid of a lift truck. prise on the base near the 3 support
points as shown in the figure below. Other points, such as the head or the accessory tray, must not be forced under any circumstances.
3.6 POSITIONING
3.6.1 Warnings for positioning
The machine must be positioned respecting the following conditions:
Unpacking and positioning
▪
the humidity and the temperature must be within the prescribed
limits (see paragraph 4.2);
▪
the fire-fighting measures must be respected;
▪
allow for sufficient space at the front, side and rear of the machine
for service or periodic maintenance and at the same time to assure
adequate air circulation. It is advisable to leave a space of about 1
metre around the machine;
▪
the place where the machine is installed must be free of corrosive/
explosive powders or gas;
▪
the place of installation must be vibration-free;
▪
the lighting must be such that the various machine functions can
clearly be seen;
▪
lift the machine and position it correctly in its final position (figure
on the side);
▪
the machine must stand on a flat rigid surface and possibly away from
any joint in the floor;
▪
the machine functions properly without having to fasten it to the floor
with wheels weighing up to 35 kg; for heavier wheels, fasten it at the
points indicated (figure on the side).
According to UNI EN 10380 regulations, the lighting for a generic working area (such as control rooms, fixed work-
stations in production plants, etc.) must on average be 300 lux (acceptable values between 200 and 500 lux). If the
machine is installed in a country different from Italy, the specific regulations in that country must be followed.
The lighting system must be such as to guarantee average lighting of 300 lux for the working environment. This
value depends on various factors, such as the characteristics of the working environment (more or less reflecting
walls and ceiling, height of the light points, etc.) and the type of bulbs used.