background image

Portable equipment

N130 / N330

Rev. 01/2019 EN 

/ Translation of the original instructions

QUICK GUIDE

BASIC 

OPERATIONS

All manuals and user guides at all-guides.com

Summary of Contents for N130

Page 1: ...Portable equipment N130 N330 Rev 01 2019 EN Translation of the original instructions QUICK GUIDE BASIC OPERATIONS All manuals and user guides at all guides com ...

Page 2: ...all guides com ...

Page 3: ...h Photocell s cable 2m length Photocell with magnetic stand Connector 1 sensor Channel A input Connector 2 sensor Channel B input N330 only Connector 3 photocell input Connector 4 micro USB port Connector 5 battery charger CONNECTION PORTS N330 INCLUDED MEASUREMENT KIT ACCELEROMETER SET PHOTOCELL SET OPTIONAL FOR N130 All manuals and user guides at all guides com ...

Page 4: ... the connector counter clockwise until it is completely extracted CONNECTION OF THE CABLES N130 N330 KEYBOARD Switch ON OFF the instrument Start Stop of the measure Confirm the chosen setup actions Function keys refer to the display Arrow keys UP DOWN LEFT RIGHT Switch channels A B only for N330 All manuals and user guides at all guides com ...

Page 5: ... parts of the machine such as support bearings All 3 orthogonal directions X Y and Z are recommended Put the reflecting tape on the shaft place the photocell on the machine casing using the magnetic stud Point the photocell spot to the reflective tape previously positioned on the shaft ACCELEROMETER PHOTOCELL Optional for N130 Sensor measurement direction All manuals and user guides at all guides ...

Page 6: ... the body with a tool for 2 seconds Tap shortly target thought LED flashing Calibration successful Align sensor spot to the target Faster flashing better reception Calibration failed PHOTOCELL CALIBRATION Optional for N130 All manuals and user guides at all guides com ...

Page 7: ... setup Tap to confirm and access to the function SENSORS SETUP 1 Define the type of sensor used choice is between ACCELEROMETER and VELOMITOR 2 Define the sensitivity of sensor used for the measure MEASURE SETUP Define all the parameters for the measure of the vibration All manuals and user guides at all guides com ...

Page 8: ...all guides com ...

Page 9: ... instrument parameters such as date time language etc NOTE Tap Arrows keys to move inside the menu and make the choices Tap DONE to confirm the setup tap BACK to leave the setup without any changes All manuals and user guides at all guides com ...

Page 10: ...screen is different depending of the function in use Tap keys or to scroll the MENU options Tap to select the desired MENU option From the MAIN MENU select the required measure function this is applicable to VIBROMETER FFT CBA TACHO After to start up the monitored rotating machine tap to start the acquisition When the reading is stable or when you want to shut down the acquisition tap again All ma...

Page 11: ... choose the machine type Tap to confirm the selection Tap HOME to exit to the function Tap keys or to choose the foundation type Tap to confirm the selection Tap BACK to go back to machine type setup STEP No 1 CHOOSE THE MACHINE TYPE STEP No 2 CHOOSE THE FOUNDATION TYPE All manuals and user guides at all guides com ...

Page 12: ...SETUP to go back to machine type setup see step No 1 While the machine is running tap to start the acquisition Tap again to stop the acquisition Tap for HOME A tap for the MENU B STEP No 3 CHOOSE THE SPEED DETECTION MODE STEP No 4 MAKE A MEASURE Causes of vibration Overall vibration Machine judgement All manuals and user guides at all guides com ...

Page 13: ... Tap BACK to exit from the function Choose the number of bearing starting from a default point Tap keys or to choose the support number Tap to confirm the selection Tap BACK to go back to list of existing projects STEP No 1 CHOOSE OR CREATE A PROJECT STEP No 2 CHOOSE THE NUMBER OF SUPPORT BEARING All manuals and user guides at all guides com ...

Page 14: ...all guides com ...

Page 15: ...gonal direction Tap to confirm the selection Tap BACK to go back to the previous step STEP No 3 CHOOSE THE ORTHOGONAL DIRECTION For detailed information please refer to the N130 N330 user manual on the USB pen supplied with your instrument All manuals and user guides at all guides com ...

Page 16: ...13 www cemb it All manuals and user guides at all guides com ...

Page 17: ...14 Vibration analysis division All manuals and user guides at all guides com ...

Page 18: ...15 www cemb it All manuals and user guides at all guides com ...

Page 19: ...CEMB S p A Via Risorgimento 9 23826 Mandello del Lario LC Italy www cemb com Vibration analysis division Phone 39 0341 706111 e mail stm cemb com All manuals and user guides at all guides com ...