16
GB
2. Technical data
2.1 Tank
60 l
95 l
Length
[cm]:
90
100
Width
[cm]:
53
59
Height
[cm]:
38
43
Weight when empty
[kg]:
19
22
Nominal volume
[l]:
60
95
Total weight when full [kg]:
65
95
Environmental conditions:
Operating temperature range: -10 °C to +40 °C
2.2 Pump
The self-priming electric pump Cematic 12/30
EX is an electrically driven pump for the delivery
and dispensing of fuels and similar media from
storage containers.
The pump motor is equipped with a thermal
overload protection device.
Voltage (tolerance): 12 V DC (+/- 10 %)
Current:
14 A
Output:
220 W
Fuse:
30 A blade-type fuse
at the pole terminal
Max. delivery rate: 30 l/min
Electric cable:
3 m (1 pole terminal each
with + and -, 1 pole termi-
nal with earth connection)
Delivery hose:
2.7 m or 3.2 m
(electrically conductive)
2.3 Automatic delivery nozzle
Delivery nozzle connection: 1
"
female thread
with swivel joint
Delivery spout:
Ø 21 mm
1.3 Inappropriate use
i
Important!
Accordingly, inappropriate use also
includes failure to observe the notices in
these operating instructions.
F u r t h e r m o r e :
• non compliance with the regulations of the
ADR, including 1.1.3.1 c) and prevailing
national provisions
• storage and transport of liquids other than
those specified under correct use, e.g. bio-
ethanol, chemicals, oils (lubricating, hydraulic
or vegetable oil).
• operation in an explosive atmosphere.
• operation in a dusty, explosive atmosphere.
• operation below ground.
• operation in Ex-zone 0.
The filling pipe is EC type tested in accordance
with ATEX Directive 94/9/EC and approved to
EN ISO 16852 for materials in explosion group
IIA (including gasoline up to E90). The filling pipe
is identified as a protection system for
G IIA
and for all other required specifications.
1.2.2 Summary
The equipment is not intended for any other
purpose.
For safety reasons, modifications are not
allowed to the filling station (except for the
addition of accessories specially provided
by the manufacturer).
Correct usage also includes compliance with all