Electric pump 12 V / 24 V
a
Mount the pump with pump feet.
b
Fit pump on the pump support using:
4 x hex screws M6 x 20
4 x spring washer A6
4 x washer A6.4
c
Remove the protective caps from the discharge hose
and the pump. Connect the connector with the seal to
the pump‘s suction side.
d
Remove the protective cap from the connection line.
Connect the filling hose with delivery nozzle to the
connection line / spacer.
a
b
c
d
Electric pump 12 V / 24 V
with meter
a
Mount the pump with pump feet.
b
Connect the connection line to the pump 30° down-
wards. Spacer not required.
c
Fit pump on the pump support using:
4 x hex screws M6 x 20
4 x spring washer A6
4 x washer A6.4
d
Remove the protective caps from the discharge hose
and the pump. Connect the connector with the seal to
the pump‘s suction side.
e
Fit the meter to the connection line.
f
Connect the filling hose with delivery nozzle to the
meter.
a
c
d
e
f
b
6
GB