C. E. Niehoff & Co.

BRUSHLESS ALTERNATORS

Section 3:  Advanced Troubleshooting

Yes

No

For “no voltage output” condition: • with 

ener

ener

ener

ener

energize switch

gize switch

gize switch

gize switch

gize switch

, go to Chart 2, page 5.

• with 

ignition switch

ignition switch

ignition switch

ignition switch

ignition switch

, go to Chart 3, page 6.

Is there a battery isolator in the system?

Chart 1 – System Circuit

Install temporary jumper between one battery terminal and
alternator terminal on isolator. Use minimum 12 AWG wire.

Do not operate charging system more than two
minutes with jumper installed. Charging system

voltage will be abnormally high and damage other components.

START HERE

CAUTION

R

Section 3: Advanced Troubleshooting

Page 4

TG9B

Summary of Contents for C711

Page 1: ...e sure the meter leads touch source area only Prevent short circuit damage to test leads or source by not allowing meter leads to touch other pins or exposed wires in test area Be sure to use CEN tools designed especially for trou bleshooting CEN alternators when available Resistance ohm testing Set meter to proper scale Be sure to zero the meter scale or identify the meter burden by touching mete...

Page 2: ...at regulated setting as vehicle electrical loads are switched on and off Alternator output current is self limiting and will not exceed rated capacity of alternator A2 121 regulator used with all units has a 15 5 V regulator setpoint available for battery isolator applications Electromagnetic interference EMI is suppressed with internal filters to acceptable levels defined by the Society of Automo...

Page 3: ...lack lead to alternator B terminal Clamp inductive ammeter on B cable 6 Operate vehicle Operate vehicle Operate vehicle Operate vehicle Operate vehicle Observe charge voltage If voltage is at or below regulator setpoint let charging system operate for several minutes to normalize operating temperature 7 Observe charge volts and amps Observe charge volts and amps Observe charge volts and amps Obser...

Page 4: ...tch ignition switch ignition switch ignition switch go to Chart 3 page 6 Is there a battery isolator in the system Chart 1 System Circuit Install temporary jumper between one battery terminal and alternator terminal on isolator Use minimum 12 AWG wire Do not operate charging system more than two minutes with jumper installed Charging system voltage will be abnormally high and damage other componen...

Page 5: ...t for battery voltage at energize switch E terminal connection Does battery voltage exist at energize switch E circuit from alterna tor to energize switch is good Energize switch is defective Repair vehicle circuit to energize switch Continue test Yes No Repair vehicle circuit from E teminal on alternator to energize switch on engine Unplug alternator to regulator harness Plug CEN Regulator Bypass...

Page 6: ...or battery voltage at B terminal on alternator to ground then at F terminal on regula tor to ground Does battery voltage exist Yes No Repair vehicle wiring as necessary Continue test Unplug alternator to regulator harness Plug CEN Regulator Bypass Adapter A10 129 into harness plug and touch black lead to ground on alternator case If no Adapter is available connect jumper wire from socket C on the ...

Page 7: ...ator or any of these test procedures or if you need to locate a Factory Authorized Service Distributor please contact us at C E Niehoff Co 2021 Lee Street Evanston IL 60202 USA TEL 800 643 4633 USA and Canada TEL 847 866 6030 outside USA and Canada FAX 847 492 1242 E mail us at service CENiehoff com ...