Assembly and operating instructions
CENTAX-G
020G-00050…00090-F.10
M020-00009-EN
Rev. 4
CENTA Antriebe Kirschey GmbH
27 / 52
WARNING
Injury and material damage can occur as a result of:
Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.
WARNING
Injury and material damage can occur as a result of:
Hydraulic fluid spraying out
Use protective goggles.
IMPORTANT
We recommend the following mounting fluids:
For mounting:
Oil with a viscosity 300 mm
2
/s at 20°C, e.g. SKF LHMF300
For dismantling:
Oil with a viscosity 900 mm
2
/s at 20°C, e.g. SKF LHDF900
Connect the pump (
p
max
= 3000 bar
) for expanding the hub (3) to the
thread G¼ or G¾ (c).
Screw the pump for pushing on the hub to the shaft.
Build up the oil pressure to push on the hub.
WARNING
Material damage can occur as a result of:
Insufficient expanding pressure in the hub
If the expanding pressure is too low, the necessary pushing pressure is
too high.
Build up the oil pressure for expanding the hub.
Build up the oil pressure alternately until the lift path (p up) of the hub (3) is
reached (for p up and reference faces, see installation drawing).
Decrease the oil pressure for expanding the hub.
Remove the pump for expanding the hub from the hub (3).
Maintain the oil pressure for pushing on the hub for one hour.
Decrease the oil pressure for pushing on the hub.