background image

10

10

MOODLINER 1812WP User Manual

Eng

Chain connection is where the DATA OUT of one fixture connects to the DATA IN of 

the next fixture. The order in which the machines are connected is not important 

and has no effect on how a controller communicates to each of them. Use an order 

that provides for the easiest and most direct cabling.

3-Pin XLR

Pin 1: GND

Pin 2: DMX -

Pin 3: DMX +

OUTPUT

INPUT

DMX use of 3-Pin XLR Connectors

DMX Termonator

Unit 1

Unit 2

Last Unit

DMX 512

Connect machines using shielded 2-conductor twisted pair cable with 3-pin XLR 

male to female connectors. The shield connection is pin 1, while pin 2 is Data Nega-

tive (S-), and pin 3 is Data positive (S+).

 CAUTION: Wires must not come into contact with each other; otherwise the fix

-

tures will not work at all, or will not work properly.

5.4. DMX Terminator

120ohm, 1/4 W

resistor

DMX Terminator

DMX is a resilient communication protocol, however errors still 

occasionally occur. In order to prevent electrical noise from dis-

turbing and corrupting the DMX control signals, a good habit is to 

connect DMX output of last fixture in the chain to a DMX termina-

tor, especially over long signal cable runs.

The DMX terminator is simply an XLR connector with a 120Ω 

(ohm), 1/4 Watt resistor connected across Signal (-) and Signal (+), 

respectively, pins 2 and 3, which is then plugged into the output 

socket on last projector in the chain. The connections are illustrat-

ed below.

 Complimentary signal cable can transmit signals to 20 unit fixtures at most. 

Signal amplifier is a must to connect more fixtures.

5.5. 3-Pin vs 5-Pin DMX cables

DMX connection protocols used by controllers and fixtures manufacturers are not 

standardized around the world. However, two are the most common standards: 

Summary of Contents for Moodliner 1812WP

Page 1: ...ke care of it Leggete questo manuale e conservatelo per future consultazioni User Manual Manuale Utente 18x12W RGBW 4in1 LED Bar with Single Led Control ENG ITA Barra con 18 LED da 12W RGBW 4in1 con C...

Page 2: ...ever closer to professional s real requirements The CENTOLIGHT Team Gentile Cliente Grazie per aver scelto un prodotto CENTOLIGHT La nostra missione quella di soddisfare ogni possibile richiesta da p...

Page 3: ...ures 7 4 2 Product Dimensions 7 5 Product Setup 8 5 1 Rear Panel Description 8 5 2 About Power Connection 9 5 3 About Dmx Connection 9 5 4 DMX Terminator 10 5 5 3 Pin vs 5 Pin DMX cables 10 6 Menu Ope...

Page 4: ...the carrier or dealer seller immediately In addition keep the box and contents for inspection If the fixture must be returned to the manufac turer it is important that it is returned in the original m...

Page 5: ...nal WARNING Describes precautions that should be observed to prevent the danger of injury or death to the operator To protect the environment please try to recycle packing materi al and exhausted cons...

Page 6: ...e installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury or property loss y If the fixture shall be lowered from the ceiling or high j...

Page 7: ...alette of solutions that gives enhances the creativity of any light designers The light source is made of 12W RGBW 4in1 LED with high quality lens The spe cially designed housing ensures an optimum he...

Page 8: ...h the setting pages UP Button It scrolls up individual items in the selection menu and sub menus for system settings DMX address Operation Mode etc and increases values settings of parameters DOWN But...

Page 9: ...o man age DMX connections DMX output is a 3 pin XLR waterproof female socket for sending the DMX control signal to other units Please read 5 3 About Dmx Connection on page 9 for details on how to mana...

Page 10: ...at all or will not work properly 5 4 DMX Terminator 120ohm 1 4 W resistor DMX Terminator DMX is a resilient communication protocol however errors still occasionally occur In order to prevent electric...

Page 11: ...he LED bar is fully lit and the effect is the jump between the different colors with the speed set by the user 0 99 by using the UP and DOWN buttons 4 Ed00 Ed99 This is an automatic mode The LED bar i...

Page 12: ...see the assignment of each channel 7 1 9 ch DMX512 Channel Chart CH Value Instruction 1 Full Dimmer 000 255 R G B W linear Dimmer 0 100 2 Full strobe 000 255 R G B W strobe slow to fast 3 Function se...

Page 13: ...er 0 100 7 2 27CH Channel Mode Chart CH Value Instruction 1 Full Dimmer 000 255 R G B W linear Dimmer 0 100 2 Full strobe 000 255 R G B W strobe slow to fast 3 Function selection 1 0 25 No function 26...

Page 14: ...er 000 255 R Linear Dimmer 0 100 7 Green Dimmer 000 255 G Linear Dimmer 0 100 8 Blue Dimmer 000 255 B Linear Dimmer 0 100 9 White Dimmer 000 255 W Linear Dimmer 0 100 10 Dimmer 1 R G B W Dimmer 11 Dim...

Page 15: ...Running change effect 11 Dep on CH 1 6 9 196 205 Running change effect 12 Dep on CH 1 6 9 206 215 Running change effect 13 Dep on CH 1 6 9 216 225 Running change effect 14 Dep on CH 1 6 9 226 235 Runn...

Page 16: ...ixture or LED is too hot Allow fixture to cool If problem per sists contact service technician Fixture resets but does not respond correctly to controller DMX mode operation Controller not connected C...

Page 17: ...Control Panel 4 Buttons and LED Display Housing Aluminum Steel Power Connectors Waterproof Powercon Input Output DMX Connectors Waterproof 3 Pin XLR Input Output Voltage 100V 240V 50 60Hz Power consum...

Page 18: ...CENTER Via Enzo Ferrari 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the product For further i...

Page 19: ...prodotto 24 5 1 Descrizione del pannello posteriore 24 5 2 Connessioni di Rete 25 5 3 Informazioni sulle Connessioni DMX 25 5 4 Terminatore DMX 26 5 5 Cavi DMX 3 Poli 5 Poli 26 6 Funzionamento dei Me...

Page 20: ...strano segni di maltrattamento avvisare immediatamente il vettore o il rivenditore Inoltre con servare la scatola e il contenuto per una eventuale ispezione Se l apparecchiatura dovesse essere restitu...

Page 21: ...ca un terminale di messa a terra ATTENZIONE Descrive precauzioni da osservare per prevenire lesioni o morte dell operatore Per proteggere l ambiente cercare di riciclare il pi possibile il ma teriale...

Page 22: ...ione impropria pu provocare lesioni personali anche molto gravi y Se il faro deve essere alzato verso o abbassato dal soffitto o da travi sospese consigliabile usare sistemi di tralicci professionali...

Page 23: ...na ottimale dissipazione del calore durante il funzionamento Il design elegante insieme alla facilit d uso sono le giuste caratteristiche per un installazione sia da interno che da esterno La struttur...

Page 24: ...ere ripetutamente per passare da una pagina all altra Tasto UP Consente di scorrere le singole voci del menu di selezione e dei sot to menu per le impostazioni del sistema indirizzo DMX modalit operat...

Page 25: ...MX Leggere 5 3 Informazioni sulle Connessioni DMX a pagina 25 per informazioni su come collegare i cavi DMX L uscita DMX presa femmina a 3 PIN per l invio del segnale di controllo DMX ad altri fari Le...

Page 26: ...con l altro altrimenti i dispositivi non funzioneranno affatto o non funzioneranno correttamente 5 4 Terminatore DMX 120ohm 1 4 W resistenza Terminatore DMX DMX un protocollo di comunicazione resilie...

Page 27: ...9CH 23CH o 72CH 3 CC00 CC99 Modalit automatica 1 La barra LED completamente accesa e l effetto il passaggio rapido tra i vari colori con la velocit settata dall utente 0 99 usando i pulsanti UP e DOWN...

Page 28: ...14 dispositivi slave e per ciascuno si pu scegliere un ID number tramite i pulsanti UP e DOWN 15 oPrt Quando si seleziona questa funzione il dispositivo sar riconosciu to come slave 7 Assegnazioni e...

Page 29: ...on CH 1 6 9 Function selection 3 000 255 Direction control for Color Jump Scroll and Color Fade Scroll 0 127 from Right to Left 128 255 from Left to Right 5 Function speed 1 000 255 Function speed slo...

Page 30: ...epending on CH 1 6 9 246 255 Running change effect 15 Depending on CH 1 6 9 Function selection 3 000 255 Direction control for Color Jump Scroll and Color Fade Scroll 5 Function speed 1 000 255 Functi...

Page 31: ...on CH 1 146 155 Fade running change effect 7 Dep on CH 1 156 165 Running change effect 8 Dep on CH 1 6 9 166 175 Running change effect 9 Dep on CH 1 6 9 176 185 Running change effect10 Dep on CH 1 6 9...

Page 32: ...e la spina Il faro non si accende corretta mente Problema elettrico interno Contattare il Servizio di Assisten za Nessuna luce o il LED si funziona a intermittenza o si brucia trop po velocemente LED...

Page 33: ...ettagli Angolo del Fascio Luminoso 20 Angolo del Campo Luminoso 50 CRI Ra 80 Frequenza Dimmer 6kHz Dimmer Lineare 0 100 a 16 bit Modalit di controllo DMX512 Master Slave Strobo Sound Auto Modalit DMX...

Page 34: ...10 62017 Porto Recanati Italia Per inviare un prodotto al centro di assistenza necessario un numero di RMA Le spese di trasporto devono essere coperte dal proprietario del prodotto Per ulteriori infor...

Page 35: ...otto viene importato nella UE da FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy www centolight com CentoLight is a registered trademark of FRENEXPORT SPA Italy CentoLight un marchio di...

Page 36: ...Ver 1 1 July 2022 www centolight com...

Reviews: