9
9
MOODLINER 1812WP User Manual
Eng
with respectively a male and a female Powercon connector.
Each connector has 3 pins. Read the following table to identify the correspondence
between numbers, wire colors, Pins, and International Standard.
Cable (EU)
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
Earth must be connected! Always pay attention to safety! Before taking into
operation for the first time, the installation has to be approved by an expert.
This fixture is also equipped with an output powercon connector to be used as
power mains source in case of
cascade connection up to a maximum of 5 fix-
tures
.
4) DMX Input/Output Sockets
DMX Input is a IP65 3-pin XLR male socket for connection to a DMX control device.
Please read “5.3. About Dmx Connection” on page 9 for details on how to man-
age DMX connections.
DMX output is a 3-pin XLR waterproof female socket for sending the DMX control
signal to other units. Please read “5.3. About Dmx Connection” on page 9 for
details on how to manage DMX connections.
5.2. About Power Connection
y
Always make sure that the voltage of the outlet you are connecting the product
to is within the range stated in paragraph “10 - Specification” on page 17 or
rear panel of the product (AC110V-240V 50/60Hz).
y
Make sure the power cord is not crimped or damaged. Never connect this prod-
uct to a dimmer pack or rheostat.
y
Never disconnect the product from power cord by pulling or tugging on the cord.
y
To avoid electric shock, all fixtures must be connected to circuits with a suitable
ground and circuit breaker.
5.3. About Dmx Connection
When use a DMX controller, please make sure that there is no interference
sources (e.g. intercom, high frequency radio waves and radiation source).
DMX machines are designed to receive data through a serial Daisy Chain. A Daisy