14
14
SQUARE 150P User Manual
Eng
SKU
Model
Description
J708J
SQUARE IRIS-200
Manual Iris for SQUARE 150P & 6200P Profile
The manual iris is installed in the same slot used for the gobos. Of course, you have
to choose between iris or gobo as they cannot be used simultaneously.
198mm (7
.8”)
268
,7mm (10
.58”)
121mm (4.76”)
15mm
(0.59”)
Ø79mm
(3.11”)
Ø100mm
(3.94”)
1. Loosen the nut for the gobo/iris flake and then move it forward to open the slot.
2. Insert the iris inside the slot.
3. Tum on the light, adjust Zoom and Focus knobs until your get the requested
beam size.
4. Use the manual iris to reduce the beam up to 0°.
7 - M
enu
o
PeraTion
By pressing MENU button, the display will cycle through 6 menus. Press ENTER but-
ton to enter the corresponding menu, press UP or DOWN to modify current parame-
ter value. Then, press ENTER button again to save current value.
No.
Menu
Function
1
001 x
DMX-Addr
DMX512 address code setting: 001-512. When there is no incoming DMX
signal, the lower right character is an “x”; when a DMX cable is connected
to a controller, and it is set on same DMX channel, it changes to a “V”.
To change channel, use UP or DOWN; then confirm with ENTER.
2
001
L-DIMMER
Manual dimmer setting: 001-255. It is helpful when you use the fixture
without a DMX controller.
To adjust dimmer value, use UP or DOWN; then confirm with ENTER.
3
001
P-STROBE
Strobo speed adjusting: 001-255.
To change value, use UP or DOWN; then confirm with ENTER.