47
CLASSIC EDGE OUTDOOR FURNACE • OWNER'S MANUAL
4. Using a scraper, remove the Reaction Chamber door seal rope and clean
any remaining silicone adhesive from the groove. Any residue left in the
groove will interfere with the new seal.
5. Apply a liberal amount of silicone sealant into the entire Reaction
Chamber door seal groove.
6. Starting at the center of the hinge side of the Reaction Chamber door,
insert the new door seal rope into the groove, pressing it firmly into the
bead of silicone sealant. Make sure the Reaction Chamber door seal rope is
not stretched as it is pressed into the corners. Force the Reaction Chamber
door seal rope out to fill in the corners as shown.
6. When the seal has been pressed into the groove all the way around the
Reaction Chamber door, cut the end of the rope about one inch longer
than required and press it tightly against the beginning end of the rope.
7. Close the Reaction Chamber door and install the wing nut. Snug the wing
nut, but do not over-tighten.
CIRCUIT BREAKER
The circuit breaker is located in the pump access area and also serves as the
furnace disconnect. If the circuit breaker trips (turns off), reset it by turning
it on. If the circuit breaker continues to trip, a component may be faulty. It is
possible to isolate a faulty component using the following procedure.
1. Disconnect power to the outdoor furnace.
Do not proceed without testing that power is disconnected. Make sure the power
cannot be reconnected while testing components (i.e., use lock out, tag out).
2. Remove the outer airbox cover; then open the airbox cover.
3. Disconnect the wires from each of the solenoids and disconnect the fan
harness.