50
CLASSIC EDGE OUTDOOR FURNACE • OWNER'S MANUAL
1. Remove the secondary air charge tube by lifting it up and sliding it toward
the back of the outdoor furnace.
2. Remove the rope gasket; then remove the existing refractory modules.
3. Install the new refractory modules; then install a new rope gasket on top
of the refractory modules.
4. Install the new secondary air charge tube by placing it in the opening at
the front of the outdoor furnace as shown; then pull it toward the front of
the outdoor furnace to secure it in place making sure the alignment pin
fits into the alignment hole in the refractory modules.
THERMOCOUPLE
1. Disconnect power to the outdoor furnace.
Do not proceed without testing that power is disconnected. Make sure the power
cannot be reconnected while replacing the thermocouple.
2. Remove the pump access cover.
3. Disconnect the thermocouple connector; then remove the mastic tape
from the thermocouple.
4. Remove the thermocouple.
5. Install the new thermocouple until the stop collar contacts the
thermocouple tube.
Mastic Tape
NOTE: Pump and
components removed
for clarity
6. Secure the thermocouple with the mastic tape; then connect the
thermocouple connector.
7. Install the pump access cover; then connect power to the furnace.