Section 1 - Furnace Installation
HEATING MULTIPLE ZONES OR BUILDINGS
A single pump and manifold may be used to heat
more than one zone as long as the return water can be
maintained above 150°F. If the return water temperature
can not be maintained above 150°F, then a separate
pump should be used for each zone. A thermostatic
bypass valve should be installed to ensure that the water
temperature in the outdoor furnace is maintained above
150˚F.
If a manifold is used (as illustrated in Fig. 23), a swing
check valve (p/n 296) should be installed in the line at
the outlet of the pump. The swing check valve must be
installed in a vertical position with the direction of flow
as designated by the arrow on the swing check valve.
This will prevent reverse circulation and loss of heat on
multiple zones if one pump fails. Hose bibs (p/n 199)
should be installed on each supply and return manifold
(as illustrated in Fig. 23) to allow for purging air from
the zones.
Models with side panels offer three sets of supply and
return ports (for up to three zones or buildings, without
the need for manifolds) for mounting of up to three
pumps on the outdoor furnace.
NOTE: If a Taco 014 pump is used, the pump
should be mounted at the base of the outdoor
furnace and a 1-1/4" supply line to the pump
should be used to ensure adequate supply feed
to the pump.
NOTE: If the outdoor furnace is unable to maintain
a water temperature of 150˚F (66˚C) or higher,
inspect the thermostatic valve and replace if
necessary.
NOTE: A properly-sized backup furnace or boiler
should be configured to provide heat if the
outdoor furnace is out of wood or the heat load
exceeds the capacity of the outdoor furnace.
Suspended Space Heater
108
118
119
133
154
173
198
199
296
140,000 Btu Heat Exchanger
3/4" Close Nipple
3/4" Flange Kit
3/4" Tee
1/4-hp Blower & Motor
009 Pump
3/4" Ball Valve
3/4" Drain Valve
3/4" Check Valve
301
380
395
409
410
411
412
1330
Air Handle Cabinet
1-1/4" Male Adapter
Manifold
1-1/4" Close Nipple
1-1/4" Ball Valve
1-1/4" Street Elbow
1-1/4" x 1/2" Bushing
3/4" x 1" Adapter
p/n
Description
p/n
Description
© 2015 Central Boiler
1-1/4"
ThermoPEX
Typical Large System Installation
Manifold for
Large Installation
Bypass
Ball Valve
Hose Bib
Hot Supply from Pump
on Outdoor Furnace
Return to
Outdoor Furnace
Thermostatic Valve
Thermostatic
Valve
Fig. 23