Page 14
SKU 47211
for technical questions, please call 1-800-444-3353.
To perform The self-Calibration process:
Note: The 100 gram wheel weight (included) must be attached to the rim when doing
the self calibration.
Mount a balanced,
or unbalanced, wheel with “normal” dimensions onto the Wheel
Balancer.
(see figure E.)
Make the wheel distance, width, and diameter measurements on the wheel, and
enter the numeric values.
(see figures d, and f.)
At the same time, press and hold down the keys “C” and “START.” Make sure not
to release pressure on either key.
(see figure d.)
On the
inner side UNBALANCE VALUE digital display (A on the Control Board)
will appear the flashing letters “CAL” which indicates the machine is asking for
confirmation of the request for self-calibration.
NOTE: If you wish to continue the
self-calibration process you must keep the two keys mentioned in Step #3 pressed
down until the letters “CAL” stop flashing.
(see figures C, and d.)
When the letters “CAL” stop flashing, release the keys “C” and “START.” Then, de-
press the “START” key only, and immediately release pressure on the “START” key,
to begin the first cycle of self-calibration.
(see figures C, and d.)
At the end of the first cycle of self-calibration, add a 100 gram weight. At the
same time, the
outer side UNBALANCE VALUE digital display LED’s will flash (B
on the Control Board). At this time, use the correct keys to enter a weight of 3.5
ounces (or 100 grams) to the
outer side UNBALANCE VALUE.
(see figures C, and d.)
Depress the “START” key only, and immediately release pressure on the “START’
key. The machine will now be fully calibrated at the end of this cycle, and on the
inner side UNBALANCE VALUE digital display (A on the Control Board) will ap-
pear the flashing letters “END CAL” which indicates the self-calibration process is
completed.
(see figures C, and d.)
Note: The information that the Wheel Balancer records from the self-calibration process is
automatically stored and maintained in its memory bank. Even so, the self-calibration
process can be repeated as often as is desired or whenever the correct functioning
of the machine is in doubt.