Page 12
For technical questions, please call 1-800-444-3353.
Item 61373
SAFET
y
Op
ERA
TION
M
AINTENAN
c
E
SETU
p
Troubleshooting
problem
possible causes
Likely Solutions
Tool will not start. 1. Power Cable not connected.
2. No power at outlet.
3. Tool’s overload protection device has
tripped to protect tool from damage.
4. Internal damage or wear. (Carbon
brushes or switch, for example.)
1. Check that Power Cable is plugged in.
2. Check power at outlet. If outlet is unpowered,
turn off tool and check circuit breaker.
If breaker is tripped, make sure circuit is right
capacity for tool and circuit has no other loads.
3. Turn off and unplug tool and allow to cool for
1/2 hour, then restart. If problem is not solved,
have qualified technician service tool.
4. Have qualified technician service tool.
Wood will not
split, or splits
extremely slowly.
1. Log not positioned properly.
2. The size or hardness of the log
exceeds the machine’s capacity.
3. Cutting Wedge is dull.
4. Hydraulic fluid level is low.
5. Low maximum pressure rating
adjustment was made on the
Maximum Pressure Limiting Screw.
1. Reposition log. Refer to General
Operating Instructions on page 9.
2. Only split logs within the Log Capacity range shown
in Specifications on page 2. Capacity will be
limited on hardwood logs and green lumber.
3. Sharpen the Cutting Wedge. Refer to
Maintenance and Servicing on page 10.
4. Check fluid level and add fluid as needed.
5. Have qualified technician adjust
maximum pressure rating.
Ram vibrates,
moves erratically,
or does not
move.
1. Log Splitter not on level ground.
2. Hydraulic fluid level is low.
3. Excessive air trapped in
the hydraulic system.
1. Reposition tool so it is level with
both ends at same height.
2. Check fluid level and add fluid as needed.
3. Bleed hydraulic system. Refer to Bleeding
the Hydraulic System on page 11. Be sure
Vent Plug is loose when operating tool.
Fluid leaking
from hydraulic
system.
1. Accumulated air is trapped in
hydraulic system while operating.
2. Tool moved with Vent Plug loosened.
3. Drain Bolt not tightened securely.
4. Hydraulic fittings and/or
seals are worn.
1. Loosen Vent Plug before operating tool.
2. Tighten Vent Plug before moving tool.
3. Tighten the Drain Bolt.
4. Have qualified technician service tool.
Follow all safety precautions whenever diagnosing or servicing the tool.