background image

SKU 94029

For technical questions, please call 1-800-444-3353.

Page 3

3.

Keep bystanders, children, and visitors away while operating a power tool.

Distractions can cause you to lose control.  Protect others in the work area from
debris such as chips and sparks.  Provide barriers or shields as needed.

presence of flammable liquids, gases, or dust.  

Power tools create sparks

which may ignite flammables.

ELECTRICAL SAFETY

4.

Grounded tools must be plugged into an outlet properly installed and
grounded in accordance with all codes and ordinances.  Never remove the
grounding prong or modify the plug in any way.  Do not use any adapter
plugs.  Check with a qualified electrician if you are in doubt as to whether
the outlet is properly grounded.

  If the tools should electrically malfunction or

break down, grounding provides a low resistance path to carry electricity away
from the user.

5.

Double insulated tools are equipped with a polarized plug (one blade is
wider than the other).  This plug will fit in a polarized outlet only one way.  If
the plug does not fit fully in the outlet, reverse the plug.  If it still does not
fit, contact a  qualified electrician to install a polarized outlet.  Do not
change the plug in any way.

  Double insulation       eliminates the need for the

three wire grounded power cord and grounded power supply system.

6.

Avoid body contact with grounded surfaces such as pipes, radiators,
ranges, and refrigerators.  

There is an increased risk of electric shock if your

body is grounded.

7.

Do not expose power tools to rain or wet conditions.  

Water entering a power

tool will increase the risk of electric shock.

8.

Do not abuse the Power Cord.

  

Never use the Power Cord to carry the tools

or pull the Plug from an outlet.  Keep the Power Cord away from heat, oil,
sharp edges, or moving parts.  Replace damaged Power Cords immedi-
ately.

  Damaged Power Cords increase the risk of electric shock.

9.

When operating a power tool outside, use an outdoor extension cord
marked “W-A” or “W”.   

These extension cords are rated for outdoor use, and

reduce the risk of electric shock.

PERSONAL SAFETY

10.

Stay alert.  Watch what you are doing, and use common sense when oper-

Summary of Contents for 94029

Page 1: ...VENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Copyright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein ma...

Page 2: ...ll instructions listed in the following pages may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS WORK AREA 1 Keep your work area clean and well lit Cluttered benches and d...

Page 3: ...This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install a polarized outl...

Page 4: ...roper footing and balance enables better control of the power tool in unexpected situations 15 Use safety equipment Always wear eye protection Dust mask nonskid safety shoes hard hat or hearing protec...

Page 5: ...s Follow instructions in the Inspection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or i...

Page 6: ...r cleaning procedures 8 WARNING People with pacemakers should consult their physician s before using this product Operation of electrical equipment in close proximity to a heart pacemaker could cause...

Page 7: ...a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool or equipment should electrically malfunction or break down grounding provides a l...

Page 8: ...n loss of power and possible tool damage See Figure C next page 3 The smaller the gauge number of the wire the greater the capacity of the cord For example a 14 gauge cord can carry a higher current t...

Page 9: ...boratories Inc Volts Alternating Current Amperes No Load Revolutions Per Minute RPM FIGURE C no RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT NAMEPLATE AMPERES At Full Load EXTENSION COR...

Page 10: ...unting holes in the Machine Base 41 Then secure each Caster to the Machine Base using four Lock Washers 37 and four Cap Nuts 36 See Assy Diagram To Attach The Collector Bag To The Collector Body To at...

Page 11: ...re F next page 2 Insert the Safety Key 7 into the Power Switch 8 and check to make sure the Power Switch is in its OFF position Then plug the Power Cord Plug 1 into the nearest 120 volt grounded elect...

Page 12: ...and any other condition that may affect its safe opera tion If abnormal noise or vibration occurs have the problem corrected before further use Do not use damaged equipment 3 Daily With a soft brush...

Page 13: ...re F previous page Part Description Qty Part Description Qty 1 Power Cord 1 23 Collector Bag 1 2 Cord Clamp 1 24 Clamp 1 3 Brush Cover 2 25 Inlet Cover 1 4 Carbon Brush 2 26 Safety Screen 1 5 Washer 1...

Page 14: ...ASSEMBLY DIAGRAM NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Reviews: