background image

Page 4

For technical questions, please call 1-800-444-3353.

Item 60754 

        

SAFET

y

M

AINTENAN

c

E

PARTS LIST

SETUP

Air compressor Safety Warnings

1. 

Risk of fire or explosion - do not spray flammable 

liquid in a confined area or towards a hot surface.  

Spray area must be well-ventilated.  Do not 

smoke while spraying or spray where spark or 

flame is present.  Arcing parts - keep compressor 

at least 20 feet away from explosive vapors, 

such as when spraying with a spray gun.

2. 

Risk of bursting - do not adjust regulator higher 

than marked maximum pressure of attachment.

3. 

Risk of injury - do not direct air 

stream at people or animals.

4. 

Do not use to supply breathing air.

5. 

Do not leave compressor unattended 

for an extended period while plugged in.  

Unplug compressor after working.

6. 

Keep compressor well-ventilated.  

Do not cover compressor during use.

7.  Drain tank daily and after use.  Internal rust causes 

tank failure and explosion.

8.  Add correct amount of compressor oil before first 

use and every use.  Operating with low or no oil 

causes permanent damage and voids warranty.

9.  Do not remove the valve cover or 

adjust internal components.

10. Compressor head gets hot during operation.  

Do not touch it or allow children nearby during 

or immediately following operation.

11.  Do not use the air hose to move the compressor.

12. Release the pressure in the 

storage tank before moving.

13. The use of accessories or attachments not 

recommended by the manufacturer may 

result in a risk of injury to persons.

14. All air line components, including hoses, pipe, 

connectors, filters, etc., must be rated for a minimum 

working pressure of 150 PSI, or 150% of the 

maximum system pressure, whichever is greater.

15. USE OF AN EXTENSION CORD IS NOT 

RECOMMENDED.  If you choose to use an 

extension cord, use the following guidelines:

TABLE A:  REcOMMENDED MINIMUM WIRE 

GAUGE FOR EXTENSION cORDS 

(120 VOLT)

NAMEPLATE 

AMPERES

(at full load)

EXTENSION cORD 

LENGTH

25′

50′

100′

150′

0 – 6

18

16

16

14

6.1 – 10

18

16

Do not use.

10.1 – 12

16

16

Do not use.

12.1 – 16

14

12

Do not use.

a.  Make sure your extension cord 

is in good condition.

b.  Be sure to use an extension cord which is heavy 

enough to carry the current your product will draw.  

An undersized cord will cause a drop in line 

voltage resulting in loss of power and overheating.  

Table A shows the correct size to use depending 

on cord length and nameplate ampere rating.  

If in doubt, use the next heavier gauge.  The 

smaller the gauge number, the heavier the cord.

16. Operate unit on level surface.  Check oil level 

daily and fill to marked level if needed.

17. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to heart pacemaker could cause 

pacemaker interference or pacemaker failure.

 SAVE THESE INSTRUcTIONS.

Summary of Contents for 60754

Page 1: ......

Page 2: ...fire and or serious injury Save all warnings and instructions for future reference The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions a...

Page 3: ...milarly rated pump on an existing compressor that includes all other needed components Constructing a new compressor using this pump is not covered by this manual 2 Use Safety Guard for Pulleys The Ai...

Page 4: ...ose to move the compressor 12 Release the pressure in the storage tank before moving 13 The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to pers...

Page 5: ...h of pressure CFM Cubic Feet per Minute flow SCFM Cubic Feet per Minute flow at standard conditions NPT National pipe thread tapered NPS National pipe thread straight Double Insulated Canadian Standar...

Page 6: ...DEATH FROM IMPROPER INSTALLATION ONLY a qualified engineer with appropriate certifications may attempt designing a new compressor to ensure that all required safety and control elements are in place a...

Page 7: ...or engine and related hardware and equipment It must also be capable of withstanding the vibration and tension of the drive belt 1 Place the Air Compressor Pump on the mounting surface at the same lev...

Page 8: ...ave a clearance of about one inch from the moving parts The safety guard must be sturdy enough to prevent injury WARNING Avoid serious injuries Do not operate this Air Compressor Pump without a safety...

Page 9: ...ir Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler a...

Page 10: ...ibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of u...

Page 11: ...r condition that may affect its safe operation 2 AFTER USE wipe external surfaces of the compressor with a clean cloth Maintenance Schedule Following are general guidelines for maintenance checks of t...

Page 12: ...2 Remove the Oil Fill Plug to allow air flow into the Pump 3 Remove the Oil Drain Plug allowing the oil to drain into the container 4 When the oil is completely drained from the Pump replace the Oil...

Page 13: ...or incorrect type 3 Crankcase oil level too low 4 Unusually dusty environment 5 Unit not on level surface 1 Check inlet and outlet filters Clean and or replace as needed 2 Drain oil and refill to pro...

Page 14: ...er 1 57 Valve Plate 2 58 Valve Seat 1 59 Valve Plate 1 60 Cylinder Gasket 1 61 Bolt 4 62 Cylinder 1 63 Compression Ring 1 64 Air ring 1 65 Oil ring 1 66 Piston Pin Clip 1 67 Piston Pin 1 68 Piston Pin...

Page 15: ...0754 Safety Maintenance PARTS LIST Setup Assembly Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 5...

Page 16: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take...

Reviews: