Page 5

For technical questions, please call 1-888-866-5797.

ITEM 61454 

        

Sa

Fety

Setup

Opera

ti

O

n

Maintenance

Grounding

tO preVent eLectric SHOcK anD DeatH  

FrOM incOrrect GrOunDinG Wire cOnnectiOn: 

check with a qualified electrician if you are in doubt as to whether the outlet is properly 

grounded.  Do not modify the power cord plug provided with the compressor.   

never remove the grounding prong from the plug.  Do not use the compressor if the power cord or plug is 

damaged.  if damaged, have it repaired by a service facility before use.  if the plug will not fit the outlet, 

have a proper outlet installed by a qualified electrician.

110-120 Vac Grounded compressors: 

compressors with three prong plugs

1.  In the event of a malfunction or breakdown, 

grounding provides a path of least resistance for 

electric current to reduce the risk of electric shock.   

This compressor is equipped with an electric 

cord having an equipment-grounding conductor 

and a grounding plug.  The plug must be 

plugged into a matching outlet that is properly 

installed and grounded in accordance 

with all local codes and ordinances.

2.  Do not modify the plug provided –  

if it will not fit the outlet, have the proper 

outlet installed by a qualified electrician.

3.  Improper connection of the equipment-grounding 

conductor can result in a risk of electric shock.  

The conductor with insulation having an outer 

surface that is green with or without yellow 

stripes is the equipment-grounding conductor.  

If repair or replacement of the electric cord or 

plug is necessary, do not connect the equipment-

grounding conductor to a live terminal.

4.  Check with a qualified electrician or service 

personnel if the grounding instructions are 

not completely understood, or if in doubt as to 

whether the compressor is properly grounded.

5.  Use only 3-wire extension cords that have 

3-prong grounding plugs and 3-pole receptacles 

that accept the compressor’s plug.

6.  Repair or replace damaged or 

worn cord immediately.

125 Vac 3-prong plug and Outlet

(for up to 125 Vac and up to 15 a)

Grounding 

pin

7.  This compressor is intended for use on a 

circuit that has an outlet that looks like the one 

illustrated above in 

125 Vac 3-prong plug 

and Outlet

.  The compressor has a grounding 

plug that looks like the plug illustrated above 

in 

125 Vac 3-prong plug and Outlet

.

8.  The outlet must be properly installed and grounded 

in accordance with all codes and ordinances.

9.  Do not use an adapter to connect this 

compressor to a different outlet.

Symbology

pSi

Pounds per square inch of pressure

cFM

Cubic Feet per Minute flow

ScFM

Cubic Feet per Minute flow 

at standard conditions

npt

National pipe thread, tapered

npS

National pipe thread, straight

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

Vac

Volts Alternating Current

a

Amperes

Summary of Contents for 61454

Page 1: ...e for future reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2013 by Harbor Frei...

Page 2: ...ymbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoid...

Page 3: ...use this compressor while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a compressor may result in serious personal injury b Use personal...

Page 4: ...is greater 15 USE OF AN EXTENSION CORD IS NOT RECOMMENDED If you choose to use an extension cord use the following guidelines Table A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT NAMEP...

Page 5: ...risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric...

Page 6: ...n before set up or use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the Air Compressor from its electrical outlet before assembling or makin...

Page 7: ...ick Coupler and fully open all regulators and valves b Plug in the Power Cord c Turn the Power Switch ON d Let the unit run for 30 minutes Air will expel freely through the Coupler e Turn the Power Sw...

Page 8: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Page 9: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Page 10: ...above on the sight glass 3 To add oil a Remove the Oil Plug 37 b Using a funnel to avoid spills pour enough oil into the Pump Crankcase 39 to reach the full level in the Oil Sight Glass 33 c Replace t...

Page 11: ...pressor Area Set Up 1 Designate a work area that is clean and well lit The work area must not allow access by children or pets to prevent injury 2 Locate the Compressor on a flat level surface to ensu...

Page 12: ...switch The Compressor will turn on automatically when the air pressure drops to 95 PSI and will turn off automatically when the air pressure reaches 125 PSI WARNING TO PREVENT SERIOUS INJURY AND DEAT...

Page 13: ...f the Compressor automatically shuts off before reaching its normal cutoff pressure a Shut off all tools b Wait until the Compressor cools down about 10 minutes c If the unit does not start up again o...

Page 14: ...surfaces of the compressor with a clean cloth 3 WARNING If the supply cord of this compressor is damaged it must be replaced only by a qualified service technician Maintenance Schedule Following are g...

Page 15: ...regulations Draining Moisture from the Tank The Drain Valve is located under the Tank It must be used daily to release all trapped air and moisture from the Tank This will eliminate condensation which...

Page 16: ...that circuit matches compressor requirements 2 Drain oil and refill to proper level with recommended oil 3 Move compressor to a warmer location Check that recommended oil is in crankcase 4 Listen for...

Page 17: ...l surface Moisture in discharge air Too much moisture in air Install inline air filter dryer and or relocate to less humid environment Oil in discharge air 1 Crankcase oil too thin or crankcase overfi...