emergency Depressurization
If it is necessary to quickly
depressurize
the Compressor, turn the Power Switch OFF�
Then, pull on the ring on the Safety Valve to quickly release stored air pressure�
automatic Shut off System
1� If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a� Shut off all tools� Turn power switch off�
b� Wait until the Compressor
cools down (10-20 minutes)�
c� Resume operation�
2� Possible causes of repeated automatic
shut off of the compressor are:
a� Using an extension cord that
is too long or narrow;
b� An air leak or open hose causing the compressor
to cycle too often and build up heat�
3� Correct any issues before further use to
avoid damage to the compressor�