Page 6

For technical questions, please call 1-888-866-5797.

Item 62380 

        

Sa

Fety

Opera

ti

O

n

Maintenance

Setup

Grounding

tO preVent eLectric SHOcK anD DeatH  

FrOM incOrrect GrOunDinG Wire cOnnectiOn: 

check with a qualified electrician if you are in doubt as to whether the outlet is 

properly grounded.  Do not modify the power cord plug provided with the compressor.  

never remove the grounding prong from the plug.  Do not use the compressor if the power cord or plug 

is damaged.  if damaged, have it repaired by a service facility before use.  if the plug will not fit the outlet, 

have a proper outlet installed by a qualified electrician.

110-120 Vac Grounded compressors: compressors with three prong plugs

1�  In the event of a malfunction or breakdown, 

grounding provides a path of least resistance for 

electric current to reduce the risk of electric shock�   

This compressor is equipped with an electric 

cord having an equipment-grounding conductor 

and a grounding plug�  The plug must be 

plugged into a matching outlet that is properly 

installed and grounded in accordance 

with all local codes and ordinances�

2�  Do not modify the plug provided –  

if it will not fit the outlet, have the proper 

outlet installed by a qualified electrician�

3�  Improper connection of the equipment-grounding 

conductor can result in a risk of electric shock�  

The conductor with insulation having an outer 

surface that is green with or without yellow 

stripes is the equipment-grounding conductor�  

If repair or replacement of the electric cord or 

plug is necessary, do not connect the equipment-

grounding conductor to a live terminal�

4�  Check with a qualified electrician or service 

personnel if the grounding instructions are 

not completely understood, or if in doubt as to 

whether the compressor is properly grounded�

5�  Use only 3-wire extension cords that have 

3-prong grounding plugs and 3-pole receptacles 

that accept the compressor’s plug�

6�  Repair or replace damaged or 

worn cord immediately�

Grounding 

pin

125 Vac 3-prong plug and Outlet

(for up to 125 Vac and up to 15 a)

7�  This compressor is intended for use on a 

circuit that has an outlet that looks like the one 

illustrated above in 

125 Vac 3-prong plug 

and Outlet

�  The compressor has a grounding 

plug that looks like the plug illustrated above 

in 

125 Vac 3-prong plug and Outlet

8�  The outlet must be properly installed and grounded 

in accordance with all codes and ordinances�

9�  Do not use an adapter to connect this 

compressor to a different outlet�

Symbology

pSi

Pounds per square inch of pressure

cFM

Cubic Feet per Minute flow

ScFM

Cubic Feet per Minute flow 

at standard conditions

npt

National pipe thread, tapered

npS

National pipe thread, straight

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc�

V

Volts

~

Alternating Current

a

Amperes

Summary of Contents for 62380

Page 1: ...ace for future reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2014 by Harbor Fr...

Page 2: ...symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avo...

Page 3: ...rating this compressor Do not use this compressor while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a compressor may result in serious p...

Page 4: ...t touch it or allow children nearby during or immediately following operation 10 Do not use the air hose to move the compressor 11 Release the pressure in the storage tank before moving 12 The use of...

Page 5: ...d consult their physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure 19 WARNING The brass components of this prod...

Page 6: ...risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric...

Page 7: ...fety Operation Maintenance Setup Specifications Electrical Rating 120VAC 60Hz 9 7A Air Outlet Size 1 4 18 NPT Air Pressure Shut off 150 PSI Restart 120 PSI Air Tank Capacity 6 Gallons Air Flow Capacit...

Page 8: ...Into Use Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions Handle Safety...

Page 9: ...nnect a regulator valve an inline shut off valve and a 1 4 NPT air hose to the Quick Coupler all sold separately The air hose must be long enough to reach the work area with enough extra length to all...

Page 10: ...ir Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler a...

Page 11: ...ibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of u...

Page 12: ...not use the Air Compressor unless all connections are air tight the extra air leaking out will cause the compressor to operate too often increasing wear on the compressor Note As long as the Power Swi...

Page 13: ...c Shut off System 1 If the Compressor automatically shuts off before reaching its normal cutoff pressure a Shut off all tools Turn power switch off b Wait until the Compressor cools down 10 20 minutes...

Page 14: ...h 3 All the bearings in this tool are lubricated with a sufficient amount of high grade lubricant for the life to fht eunit under normal conditions Therefore no further lubrication of the bearings is...

Page 15: ...ing to remove valve may cause serious personal injury 9 Turn off drain valve until completely closed Checking the Safety Valve DANGER Do not attempt to tamper with the safety valve Anything loosened f...

Page 16: ...eck that circuit matches compressor requirements 2 Move compressor to a warmer location 3 Listen for air leaking from valve If leaking replace with identical valve with same rating DO NOT SEAL OR TAMP...

Page 17: ...ory CFM you need a larger Compressor Excessive noise vibration 1 Loose fittings 2 Unit not on level surface 1 Reduce air pressure then check all fittings with a soap solution for air leaks and tighten...

Page 18: ...M6 3 53 Screw M5x12 8 54 Rubber Foot 4 55 Drain Valve 1 56 Handle 1 57 Shroud 1 58 Tapping Screw St4x12 2 59 Press Fixture 1 60 Power Switch 1 61 Power Cord 1 62 Cable Connector U 2 63 Cable Connecto...

Page 19: ...Item 62380 Safety Operation Maintenance Setup Assembly Diagram 34 35 36 37 38 39 35 40 41 44 45 56 32 33 31 30 12 13 15 16 17 11 10 7 8 9 6 5 4 3 2 1 7 19 20 21 22 14 26 27 28 29 25 24 23 42 43 18 49...

Page 20: ...of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES...

Reviews: