For technical questions, please call 1-888-866-5797.
Item 62913
SAFETY
Op
ERA
TION
M
AINTENANCE
INST
ALLA
TION
Grounding
TO pREVENT ELECTRIC SHOCK AND DEATH
FROM INCORRECT GROUNDING WIRE CONNECTION:
Check with a qualified electrician if you are in doubt as to whether the is properly grounded. Do
not use the compressor if the power cord is damaged. If damaged, have it repaired by a service
facility before use.
Symbology
pSI
Pounds per square inch of pressure
CFM
Cubic Feet per Minute flow
SCFM
Cubic Feet per Minute flow
at standard conditions
NpT
National pipe thread, tapered
NpS
National pipe thread, straight
RpM
Revolutions Per Minute
Hp
Horsepower
WARNING marking concerning Risk
of Eye Injury. Wear ANSI-approved
safety goggles with side shields.
WARNING marking concerning
Risk of Respiratory Injury.
Operate engine OUTSIDE and far
away from windows, doors, and vents.
WARNING marking concerning
Risk of Explosion.
Specifications
Pump
Two stage
Air Outlet Size
1/2″ -18 NPT
Air Pressure
Shut-off 180 PSI
Restart 140 PSI
Air Tank Capacity
30 Gallons
Air Flow Capacity
18 SCFM @ 90 PSI
19.5 SCFM @ 40 PSI
Oil Capacity
57 oz. (1.7L)
Oil Type
SAE 30 non-detergent
Air Compressor Oil
Required Rotation
viewed from PTO
(power takeoff - the output shaft)
Clockwise
Required Engine
Idle Speed
2000 RPM ± 100 RPM
Note: Engine specifications are found in the engine manual supplied with this equipment.