background image

Page 4

For technical questions, please call 1-800-444-3353.

SKU 67708 

        

compressor.  keep cord away from 

heat, oil, sharp edges or moving 

parts.  

Damaged or entangled cords 

increase the risk of electric shock.

3. 

Personal safety

a. 

Stay alert, watch what you are 

doing and use common sense when 

operating this compressor.  do 

not use this compressor while you 

are tired or under the influence of 

drugs, alcohol or medication.

  A 

moment of inattention while operating 

a compressor may result in serious 

personal injury.

b. 

use personal protective equipment.  

always wear anSI-approved eye 

protection during setup and use.

c. 

Prevent unintentional starting.  

ensure the switch is in the off-

position before connecting to power 

source or moving the compressor.

4. 

compressor use and care

a. 

do not use the compressor if the 

switch does not turn it on and 

off.

  Any compressor that cannot be 

controlled with the switch is dangerous 

and must be repaired.

b. 

disconnect the plug from the 

power source before making any 

adjustments, changing accessories, 

or storing the compressor.

  Such 

preventive safety measures reduce 

the risk of starting the compressor 

accidentally.

c. 

Store an idle compressor out of 

the reach of children and do not 

allow persons unfamiliar with the 

compressor or these instructions to 

operate it.

  A compressor is dangerous 

in the hands of untrained users.

d. 

maintain the compressor.  keep 

the compressor clean for better 

and safer performance.  Follow 

instructions for lubricating and 

changing accessories.  keep dry, 

clean and free from oil and grease.  

check for misalignment or binding 

of moving parts, breakage of parts 

and any other condition that may 

affect the compressor’s operation.  

If damaged, have the compressor 

repaired before use.

  Many accidents 

are caused by a poorly maintained 

compressor.

e. 

use the compressor in accordance 

with these instructions, taking into 

account the working conditions and 

the work to be performed.

  Use of 

the compressor for operations different 

from those intended could result in a 

hazardous situation.

5. 

Service

a. 

Have your compressor serviced by 

a qualified repair person using only 

identical replacement parts.

  This will 

ensure that the safety of the compressor 

is maintained.

air compressor Safety Warnings

1. 

Risk of fire or explosion - do not 

spray flammable liquid in a confined 

area or towards a hot surface.  Spray 

area must be well-ventilated.  do not 

smoke while spraying or spray where 

spark or flame is present.  Arcing 

parts - keep compressor at least 20 

feet away from explosive vapors, 

such as when spraying with a spray 

gun.

2. 

risk of bursting - do not adjust 

regulator higher than marked 

maximum pressure of attachment.

3. 

risk of injury - do not direct air 

stream at people or animals.

4. 

do not use to supply breathing air.

Summary of Contents for 67708

Page 1: ...l rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manu...

Page 2: ...ing 8 Instructions for putting into use 8 Functions 8 Assembly Mounting 9 Checking the Oil 10 General Operating Instructions 11 Compressor Area Set Up 11 General Operation 11 Emergency Depressurizatio...

Page 3: ...ided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to per...

Page 4: ...to operate it A compressor is dangerous in the hands of untrained users d Maintain the compressor Keep the compressor clean for better and safer performance Follow instructions for lubricating and cha...

Page 5: ...0 PSI or 150 of the maximum system pressure whichever is greater 15 USE OF AN EXTENSION CORD IS NOT RECOMMENDED If you choose to use an extension cord use the following guidelines RECOMMENDED MINIMUM...

Page 6: ...the plug will not fit the outlet have a proper outlet installed by a qualified electrician 110 120 V Grounded Compressors Compressors with Three Prong Plugs 1 In the event of a malfunction or breakdo...

Page 7: ...plug illustrated above in 125 V 3 Prong Plug and Outlet 8 The outlet must be properly installed and grounded in accordance with all codes and ordinances 9 Do not use an adapter to connect this compres...

Page 8: ...ant Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product To prevent serious injury from accidental operation Tur...

Page 9: ...minutes Air will expel freely through the Coupler e Turn the Power Switch OFF f Unplug the Power Cord and remove the male coupler 5 Connect a regulator valve an inline shut off valve and a 1 4 NPT air...

Page 10: ...hown above on the sight glass 3 To add oil a Remove the Oil Plug b Using a funnel to avoid spills pour enough oil into the Pump Crankcase to reach the full level in the Oil Sight Glass c Replace the O...

Page 11: ...ild up pressure until it cycles off Note At the beginning of the day s first use of the Air Compressor check for air leaks by applying soapy water to connections while the Air Compressor is pumping an...

Page 12: ...is necessary to quickly depressurize the Compressor turn the Power Switch OFF Then pull on the ring on the Safety Valve 73 to quickly release stored air pressure Automatic Shut off System 1 Reset But...

Page 13: ...rfaces of the compressor with a clean cloth 3 WARNING If the supply cord of this compressor is damaged it must be replaced only by a qualified service technician Maintenance Schedule Following are gen...

Page 14: ...the FULL level on the Oil Sight Glass f Replace and tighten the Oil Breather Plug g Discard the old oil according to local state and federal regulations Draining Moisture from the Tank The Drain Valve...

Page 15: ...Check that circuit matches compressor requirements 2 Drain oil and refill to proper level with recommended oil 3 Move unit to a warmer location Check that recommended oil is in crankcase 4 Listen for...

Page 16: ...needed Do not overtighten Excessive noise 1 Crankcase overfilled with oil or oil is incorrect thickness or type 2 Crankcase oil level too low 3 Loose or damaged belt guard 4 Loose fittings 5 Unit not...

Page 17: ...parts of the product In fact the manufacturer and or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians and not by the buy...

Page 18: ...Glass 1 34 O Ring 1 35 Drain Plug M5 x 10 1 36 O Ring 1 37 Oil Breather Plug 1 38 Crankcase Cover Gasket 1 39 Pump Crankcase 1 40 Washer M5 10 41 Screw M5 x 16 10 Part Description Qty 42 Manual Overl...

Page 19: ...Page 19 For technical questions please call 1 800 444 3353 SKU 67708 ASSEMBLY DIAGRAM...

Page 20: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may...

Reviews: