SKU 90385
For technical questions, please call 1-800-444-3353.
Page 10
Empty Air and Condensation
The water Spill Valve (59) is located underneath the Air Tank. It must be used daily to re-
lease all trapped moisture through this valve. It will also get rid of any condensation that
may cause tank corrosion.
Warning: Do not open the water Spill Valve (59) so that more than four threads are
showing.
1.
Push down on the Auto/Off Pressure Switch (66) to turn the compressor off.
2.
Unscrew the water Spill Valve (59) two to three turns.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS
MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBU-
TOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE
IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACE-
MENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT
BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR
HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARIS-
ING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
INSPECTION, MAINTENANCE, AND CLEANING
1.
WARNING! Make sure the Power Switch of the Air Compressor is in its “OFF”
position and that the tool is unplugged from its electrical outlet before performing any
inspection, maintenance, or cleaning procedures.
2.
Before each use, inspect the general condition of the Air Compressor. Check for
loose screws, misalignment or binding of moving parts, cracked or broken parts,
damaged electrical wiring, and any other condition that may affect its safe operation.
If abnormal noise or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
3.
Check compressor oil level daily. Fill if necessary with 30-weight, non-detergent oil.
4.
Purge the Air Tank daily of all air and condensation to prevent corrosion.
5.
Store the Air Compressor in a clean and dry location.
6.
Check all air fittings for leaks before using.