background image

6 IN 1 AIR FRAMING NAILER

ASSEMBLY and OPERATING

INSTRUCTIONS

3491 Mission Oaks Blvd., Camarillo, CA 93011

Visit our Web site at http://www.harborfreight.com

For technical questions and replacement parts, please call 1-800-444-3353

Model  91044

Copyright

©

 2004 by Harbor Freight Tools

®

.  All rights reserved.  No portion of

this manual or any artwork contained herein may be reproduced in any shape
or form without the express written consent of Harbor Freight Tools.

®

TO PREVENT SERIOUS INJURY,

READ AND UNDERSTAND ALL WARNINGS

AND INSTRUCTIONS BEFORE USE.

Revised 07/04

Summary of Contents for 91044

Page 1: ... and replacement parts please call 1 800 444 3353 Model 91044 Copyright 2004 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Revised 07 04 ...

Page 2: ...be caught in moving parts Protective electrically nonconductive clothes and nonskid footwear are recommended when working Wear restrictive hair covering to contain long hair 7 Use eye and ear protection Always wear ANSI approved impact safety goggles Wear a full face shield if you are producing metal filings or wood chips Wear an ANSI approved dust mask or respirator when working around metal wood...

Page 3: ...hat it will operate properly and perform its intended function Check for alignment and binding of moving parts any broken parts or mounting fixtures and any other condition that may affect proper operation Any part that is damaged should be properly repaired or replaced by a qualified technician Do not use the tool if any the trigger does not operate properly 15 Guard against electric shock Preven...

Page 4: ...ls known to the State of California to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks and cement or other masonry products Arsenic and chromium from chemically treated lumber California Health Safety Code 25249 5 et seq 26 Stay within air pressure capacity Never operate the Nailer above 125 PSI 2...

Page 5: ... on the Nailer First wrap the 1 4 air connector not included with pipe thread seal tape before threading it into the Air Inlet 90 Connect the 3 8 ID Air Source Hose to the Nailer Note If you are not using an automatic oiler system before operation add a few drops of Pneumatic Tool Oil to the airline connection Add a few drops more after each hour of continual use 2 Set the air pressure on your com...

Page 6: ...the nailer at a piece of scrap wood when testing 1 Make sure the tool is disconnected from the power supply 2 Completely empty the Magazine 76 of nails 3 The Nailer should not fire if the Safety 41 is not depressed against the workpiece 4 Make sure the Trigger 47 and Safety 41 move freely without sticking 5 Connect the air supply to the tool at the Air Inlet 90 Set the regulator at the recom mende...

Page 7: ...loading or servicing FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 Exhaust Cover 4 Safety 41 Magazine 76 Trigger 47 Air Inlet 90 FIGURE 5 Plate 80 Adjustment Knob 81 Tab 70 Latch 83 Angle Adjustment Holes Hex Bolt Tab 70 Operation continued 21o 28o 34o 34o 28o 21o FIGURE 6 21o 28o 34o Pin in A 21o Position Pin in B 28o 34o Position REV 04 06 ...

Page 8: ...e 35 and reinsert and secure the Pin 34 Before using the nailer be sure that the Pin is properly secured 2 The driving depth of a nail can be adjusted in two ways First by increasing or de creasing air pressure never to exceed the maximum of 125 PSI Secondly by loos ening the Screw 37 and adjusting the Bracket A 38 We recommend you experi ment in a scrap piece of material to determine how far to a...

Page 9: ...some other way Reload the maga zine with a new nail strip Be careful When you pull back on the Latch 83 to release the Tab 70 it will spring forward with force Keep your fingers clear when you release the Latch 83 and slide the Tab 70 forward If you are unable to clear the nail jam using the method prescribed above the tool should be taken to a qualified service technician for proper servicing Fig...

Page 10: ... a compressor that delivers the proper CFM Add air tool oil not incl Check replace O rings or seals Verify screws are tight Check replace O rings seals Verify fastener size Replace fasteners Tighten screws Clean Magazine Inspect Driver Unit Symptom Top of tool or Trigger 47 leaks air Sluggish operation or will not operate Bottom of tool leaks air Frequent Jamming Cause Loose Screws Worn or damaged...

Page 11: ... 4 d a e H e v l a V r e g g i r T 0 8 e t a l P 0 2 g n i r O 0 5 g n i r p S 1 8 b o n K t n e m t s u j d A 1 2 y l b m e s s A n o t s i P 1 5 g n i r O 2 8 t r o p p u S 2 2 g n i r O 2 5 m e t S e v l a V r e g g i r T 3 8 h c t a L 3 2 r e d n i l y C 3 5 g n i r O 4 8 g n i r p S n o i s r o T 4 2 g n i r O 4 5 e d i u G e v l a V r e g g i r T 5 8 g n i h s u B 5 2 A r e p m u B 5 5 n i P...

Page 12: ...Page 12 SKU 91044 For technical questions please call 1 800 444 3353 Assembly Drawing REV 06 05 ...

Reviews: