background image

Page 3

SKU 93296

For technical questions, please call 1-800-444-3353

9.

Maintain tools with care.  Keep tools clean for better and safer performance. Follow

instructions for lubricating and changing accessories. Inspect tool cords and air hoses
periodically and, if damaged, have them repaired by an authorized technician. The
handles must be kept clean, dry, and free from oil and grease at all times.

10. Disconnect air supply. Disconnect air hose when not in use.

11. Remove adjusting keys and wrenches.  Check that keys and adjusting wrenches are

removed from the tool or machine work surface before plugging it in.

12. Avoid unintentional starting.  Be sure the trigger is released when not in use and before

plugging in. Do not carry any tool with your finger on the trigger, whether it is plugged in
or not.

13. Stay alert.  Watch what you are doing, use common sense. Do not operate any tool when

you are tired.

14. Check for damaged parts.  Before using any tool, any part that appears damaged should

be carefully checked to determine that it will operate properly and perform its intended
function. Check for alignment and binding of moving parts; any broken parts or mounting
fixtures; and any other condition that may affect proper operation. Any part that is damaged
should be properly repaired or replaced by a qualified technician. Do not use the tool if
any switch does not turn On and Off properly.

15. Guard against electric shock.  Prevent body contact with grounded surfaces such as

pipes, radiators, ranges, and refrigerator enclosures.

16. Replacement parts and accessories.  When servicing, use only identical replacement

parts. Use of any other parts will void the warranty. Only use accessories intended for
use with this tool. Approved accessories are available from Harbor Freight Tools.

17. Do not operate tool if under the influence of alcohol or drugs. Read warning labels if

taking prescription medicine to determine if your judgement or reflexes are impaired
while taking drugs.  If there is any doubt, do not operate the Impact Wrench.

18. Use proper size and type extension cord. If an extension cord is required, it must be of

the proper size and type to supply the correct current to the compressor without heating
up. Otherwise, the extension cord could melt and catch fire, or cause electrical damage
to the compressor. Check your air compressor’s manual for the appropriate size cord.

19. Maintenance.  For your safety, maintenance should be performed regularly by a qualified

technician.

20.

Compressed air only.  Never use combustible gas as a power source.

21. This Impact Wrench should only be used with impact sockets and extensions.  Using

any other accessories can cause the accessories to break, causing permanent damage
to the unit and severe injury to the operator.

Note:  Performance of the compressor (if powered by line voltage) may vary depending on

variations in local line voltage. Extension cord usage may also affect tool performance.

Summary of Contents for 93296

Page 1: ...ned herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE ASSEMBLY AND OPERATING INSTRUCTIONS Model 93296 Due to continuing improvements actual product may differ slightly from the product...

Page 2: ... When not in use tools must be stored in a dry location to inhibit rust Always lock up tools and keep out of reach of children 5 Use the right tool for the job Do not attempt to force a small tool or attachment to do the work of a larger industrial tool There are certain applications for which this tool was designed It will do the job better and more safely at the rate for which it was intended Do...

Page 3: ... turn On and Off properly 15 Guard against electric shock Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerator enclosures 16 Replacement parts and accessories When servicing use only identical replacement parts Use of any other parts will void the warranty Only use accessories intended for use with this tool Approved accessories are available from Harbor Frei...

Page 4: ...iler system before operation add a few drops of Pneumatic Tool Oil to the airline connection Add a few drops more after each hour of continual use 2 Set the air pressure on the regulator to 90 PSI Do not exceed the recommended air pressure of 90 PSI 3 Check the air connection for leaks Disconnect from the air source Operation For best service you should incorporate an oiler regulator and inline fi...

Page 5: ... Pressures above 90 PSI will strip the workpiece and damage the tool potentially causing the tool to fail causing serious injury Use other appropriate methods and tools to tighten the nut 10 When the nut is tightened release the Trigger 34 Turn off the air compressor and disconnect the hose 11 If available check the recommended torque specification for the nut Use a torque wrench to tighten the nu...

Page 6: ... possible spray it with compressed air before each use 4 Periodically add a high quality machine oil to the oil inlet by removing the Oil Screw 39 See illustration below 5 If you do not use an inline oiler filter system lubricate the tool daily by holding it so that the Air Inlet 29 is facing up Squeeze theTrigger 34 and place one or two drops of oil into the Air Inlet 29 Squeezing the Trigger 34 ...

Page 7: ... OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List t r a P n o i t p i r c s e D y t Q t r a P n o i t p i r c s e D y t Q 1 r o t o M 1 3 2 r e h s a W p a C 4 2 l a e S l i O 1 4 2 w e r c S 1 3 g n i R O 1 5 2 n i P e v l a V 1 4 r e n i a t e R t e k c o S 1 6 2 g n i R O 1 5 h s u B e l d n i p S 1 7 2 l l a B l e e t S 1 6 k n a h S l i v n A 1 8 2 g n i r p S 1 7 m a C r e ...

Page 8: ...Page 8 SKU 93296 For technical questions please call 1 800 444 3353 Assembly Drawing ...