SPECIFIC SAFETY RULES

This Dust Reclaimer Kit is designed for use only with Model 94274.

1. 

Use the right product for the job. 

2. 

 Do not attempt to force small tools and  

equipment to do the work of larger tools and equipment.  There are certain  
applications for which this Dust Reclaimer was designed.  It will do the job better 
and more safely at the rate and speed for which it was intended.  Do not modify 
this Dust Reclaimer, and do not use this product for a purpose for which it was  
not intended.  

Maintain labels and nameplates on the Dust Reclaimer.

3. 

  These carry  

important information.  If unreadable or missing, contact Harbor Freight Tools for 
a replacement.

Always wear safety impact eye goggles when assembling and using the Dust 

4. 

Reclaimer.   Also, use dust masks or a respirator when using the Dust Reclaimer.  
Using personal safety devices reduce the risk for injury. 

  

 

5. 

Maintain a safe working environment.  Keep the work area well lit.  Make sure 
there is adequate surrounding workspace.  Always keep the work area free of ob-
structions, grease, oil, trash, and other debris.  Do not use a power tool in areas 
near flammable chemicals, dusts, and vapors.  Do not use this product in a damp 
or wet location.

        WARNING:  Some dust created by power sanding, sawing, grinding, drilling, 

6. 

and other construction activities, contains chemicals known [to the State of 
California] to cause cancer, birth defects or other reproductive harm.  Some 
examples of these chemicals are: Lead from lead-based paints Crystalline silica 
from bricks and cement or other masonry products Arsenic and chromium from 
chemically treated lumber  Your risk from these exposures varies, depending on 
how often you do this type of work.  To reduce your exposure to these chemicals: 
work in a well ventilated area, and work with approved safety equipment, such as 
those dust masks that are specially designed to filter out microscopic particles. 
(California Health & Safety Code § 25249.5, 

et seq.

)         

SERVICE

23. 

Tool service must be performed only by qualified repair personnel.  Service   

           or maintenance performed by unqualified personnel could result in a risk of injury.

24. 

When servicing a tool, use only identical replacement parts.  Follow    

 

           instructions in the 

“Inspection, Maintenance, And Cleaning” 

section of this   

           manual.  Use of unauthorized parts or failure to follow maintenance instructions    
           may create a risk of electric shock or injury.

REV 07j

Summary of Contents for 94275

Page 1: ...http www harborfreight com Copyright 2007 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the expr...

Page 2: ...clean and well lit Cluttered benches and dark areas invite accidents 2 Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create...

Page 3: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 7 Do not expose power tools to rain or w...

Page 4: ...power tool if the Power Switch does not turn it on or off Any tool that cannot be controlled with the Power Switch is dangerous and must be replaced 18 Disconnect the Power Cord Plug from the power s...

Page 5: ...other debris Do not use a power tool in areas near flammable chemicals dusts and vapors Do not use this product in a damp or wet location WARNING Some dust created by power sanding sawing grinding dr...

Page 6: ...eclaimer is not intended for use with silica based abrasives Silica based abrasives have been linked to severe respiratory disease such as silicosis Always use silica substitutes such as aluminum oxid...

Page 7: ...system and must never be attached to an electrically live terminal See Figure A Your tool must be plugged into an appropriate outlet properly installed and 3 grounded in accordance with all codes and...

Page 8: ...1 either a two or three wire extension cord As the distance from the supply outlet increases you must use a heavier gauge 2 extension cord Using extension cords with inadequately sized wire causes a...

Page 9: ...res Symbology Double Insulated Canadian Standards Association Underwriters Laboratories Inc V Volts Alternating Current A Amperes n0 xxxx min No Load Revolutions per Minute RPM Make sure your extensio...

Page 10: ...supplied with the Dust Reclamer is 3 feet long When determining a permanent location for the Model 94274 Blast Cabi net make sure the Blast Cabinet is within 3 feet of the wall surface on which the Du...

Page 11: ...diameter Figure 3 1 57 1 57 9 73 NOTE The Wall Anchors 33 are intended for concrete walls If you are attaching the Dust Reclaimer Kit to drywall or wood you will need different fasteners not included...

Page 12: ...ttach the dust reclaimer to the wall using Flat Washers 35 Spring Washers 7 36 and Hex Nuts 46 See Figure 5 below Figure 5 Figure 4 Tap the Wall Anchors 33 into the wall using a hammer They will expan...

Page 13: ...800 444 3353 PAGE 13 Attach the blast cabinet to the Dust Reclaimer as shown in Figure 7 then firmly 9 tighten up the Hose Clamps 15 Figure 7 48 After attaching the Dust Reclaimer to the wall it shoul...

Page 14: ...SKU 94274 Open the right side door of the blast cabinet Remove the four screws on the ex 1 haust board Take out the Exhaust Board see to Figure 8 Install the Hose Connector 48 using four Bolts 47 as s...

Page 15: ...w Place the Support Brackets 32 on a flat surface Adjust the position of the 5 support brackets and the Dust Reclaimer hose nozzle until it looks like it does in Figure 10 below Make sure the Support...

Page 16: ...the other end of the Hose 16A over the 2 port of the Dust Reclamer Press the Dust Reclaimer all the way up against the back of the Blast Cabinet Mark the drilling hole locations through the mounting h...

Page 17: ...the Power Cord Plug 12 of the Dust Reclaimer is unplugged from its electrical outlet See Assy Diagram B Release the Latch 27 and open the Dust Collector Cap 26 at the bottom of the Dust Reclaimer The...

Page 18: ...ck to make sure Dust Reclaimer is 1 on Dust Reclaimer is filled Empty and 2 clean out Dust Reclaimer Filter in Dust Reclaimer needs to be 3 cleaned or replaced Check to make sure there is no clogging...

Page 19: ...4275 For technical questions please call 1 800 444 3353 PAGE 19 NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts ASSEMBLY DIA...

Page 20: ...of his or her installation of replacement parts thereto PLEASE READ THE FOLLOWING CAREFULLY Parts List Part Description Qty Part Description Qty 1 Radiating Guard 1 2 Screw M6x12 4 3 Motor 1 4 Tappin...

Page 21: ...or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantab...

Reviews: