Page 10
For technical questions, please call 1-800-444-3353.
SKU 95275
Close the in-line Shutoff Valve.
14.
Bleed air from the tool then disconnect it.
15.
Turn the Drain Valve, at the bottom of the
16.
Tank, two turns to release any built-up
moisture and the internal tank pressure.
Close the valve after moisture has
drained out. Do not remove the Drain
Valve.
Clean, then store the Air Compressor
17.
indoors.
Emergency depressurization
If it is necessary to quickly
depressurize
the Compressor, turn the Switch OFF.
Then, pull on the ring on the Safety Valve
to quickly release stored air pressure.
Automatic Shut off System
If the Compressor automatically shuts
1.
off:
Shut off all tools.
a.
Wait until the Compressor cools down
b.
(about 10 minutes);
Press the Reset Button to start the
c.
compressor;
Resume operation.
d.
Possible causes of repeated automatic
2.
shut off of the compressor are:
Using an extension cord that is too long
a.
or narrow;
An air leak or open hose causing the
b.
compressor to cycle too often and build
up heat.
Correct any issues before further use to
3.
avoid damage to the compressor.
MAINTENANCE ANd
SERVICING
Procedures not specifically
explained in this manual must
be performed only by a qualified
technician.
TO PREVENT
SERIOuS INjuRY
FROM ACCIdENTAL
OPERATION:
Turn the Switch “OFF”, unplug
the Compressor from its
electrical outlet, and release all
air pressure from the air tank
before performing any
inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOuS INjuRY
FROM COMPRESSOR FAILuRE:
do not use damaged equipment.
If abnormal noise or vibration
occurs, have the problem
corrected before further use.
Cleaning, Maintenance, and
Lubrication
BEFORE EACH uSE,
1.
inspect the
general condition of the Air Compressor.
Check for loose hardware, misalignment
or binding of moving parts, cracked or
broken parts, damaged electrical wiring,
and any other condition that may affect
its safe operation.
AFTER uSE,
2.
wipe external surfaces of
the compressor with a clean cloth.
3.
WARNING! If the supply cord
of this compressor is damaged, it
must be replaced only by a qualified
service technician.