Page 7
For technical questions, please call 1-800-444-3353.
SKU 95275
SPECIFICATIONS
Electrical
Requirements
120 V~ / 60 Hz / 2.6 A
Air Outlet Size
1/4” -18 NPT
Air Pressure
Auto Shut-Off @ 100 PSI
Restart @ 85 PSI
Air Tank Capacity 3 Gallons
Air Flow Capacity 0.6 SCFM @ 90 PSI
1 SCFM @ 40 PSI
Pump
Single stage
Line Cord
6’ x 18 AWG with 3-prong plug
Thermal
Protection
Motor equipped with overheat
auto shutdown
NOTE:
Allow adequate time when filling tires.
The larger the tire, the more time to fill is
needed.
NOTE:
This product is designed for inflation,
stapling, brad nailing and air brushing.
uNPACKING
When unpacking, make sure that the
item is intact and undamaged. If any parts
are missing or broken, please call Harbor
Freight Tools at 1-800-444-3353 as soon as
possible.
INSTRuCTIONS FOR PuTTING
INTO uSE
Read the ENTIRE IMPORTANT
SAFETY INFORMATION
section at the beginning of this
manual including all text under
subheadings therein before set up
or use of this product.
TO PREVENT
SERIOuS INjuRY
FROM ACCIdENTAL
OPERATION:
Turn the Switch “OFF”, unplug
the Compressor from its
electrical outlet, and release all
air pressure from the air tank
before assembling or making any
adjustments to the compressor.
Note:
For additional information regarding the
parts listed in the following pages, refer
to the Assembly Diagram near the end of
this manual.
Functions
Reset
Button
Output Air
Pressure
Gauge
Switch
Tank Air
Pressure
Gauge
Safety
Valve
Regulator
Knob
Air
Outlet
Compressor Area Set up
Designate a work area that is clean and
1.
well-lit. The work area must not allow
access by children or pets to prevent
injury.
Locate the Compressor on a flat level
2.
surface to prevent tipping and damage.
Keep at least 12” of space around the
unit to allow air circulation.
Route the power cord from the
3.
compressor to the grounded wall outlet,
along a safe path without creating a
tripping hazard or exposing the power
cord to possible damage.
REV 09i