Break in the new Air Compressor as 

1. 

follows: 

Make sure the Switch is OFF and the 

a. 

unit is unplugged. Insert a male coupler 

(sold separately) into the female Quick 

Coupler and fully open all regulators 

and valves.
Plug in the Power Cord.

b. 

Turn the Switch ON (the 

c. 

|

 position) 

and press the Reset button next to the 

Switch.
Let the unit run for 30 minutes. Air will 

d. 

expel freely through the Coupler.
Turn the Switch OFF.

e. 

Unplug the Power Cord and remove the 

f. 

male coupler.

Typical Air Line Setup

Recommeded Accessories

1/4” Air Hose

• 

Set of 1/4” Male and Female Quick Couplers

• 

Inline Desiccant Dryer/Filter or Water Filter

• 

Female 

Quick Coupler

Female 

Quick Coupler

1/4” Air Hose

Water Filter 

(Airbrush Use)

Male 

Quick 

Coupler

Male 

Quick 

Coupler

Air  

Compressor

Tool

2.  Connect a regulator valve, an inline 

shut off valve and a 1/4” NPT air hose 

to the Quick Coupler. The air hose must 

be long enough to reach the work area 

with enough extra length to allow free 

movement while working.

Note:

 

An in-line shutoff ball valve is an 

important safety device because it 

controls the air supply even if the air 

hose is ruptured.  The shutoff valve 

should be a ball valve because it can 

be closed quickly.

Depending on the tool which you will 

3. 

be using with this compressor, you 

may need to incorporate additional 

components, such as an in-line oiler, 

a filter, or a dryer (all sold separately). 

Consult your air tool’s manual for needed 

accessories.

GENERAL OPERATING 

INSTRuCTIONS

  Read the ENTIRE IMPORTANT 

SAFETY INFORMATION 

section at the beginning of this 

manual including all text under 

subheadings therein before set up 

or use of this product.

1.  Turn red regulator knob counterclockwise 

completely. 
Close drain valve. 

2. 

Plug the Air Compressor Power Cord 

3. 

into a grounded 120 V electrical outlet.

REV 10b

Summary of Contents for 95275

Page 1: ...rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For tec...

Page 2: ... moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury General Safety Warnings WARNING Read all safety warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for...

Page 3: ...n the compressor Keep d the compressor clean for better and safer performance Follow instructions for lubricating and changing accessories Keep dry clean and free from oil and grease Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the compressor s operation If damaged have the compressor repaired before use Many accidents are caused by a ...

Page 4: ...on cord is in a good condition Use an extension cord which is heavy b enough to carry the current your product will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating Table A shows the correct size to use depending on cord length and nameplate ampere rating If in doubt use the next heavier gauge The smaller the gauge number the heavier the cord Ind...

Page 5: ...odify the plug provided if it will 2 not fit the outlet have the proper outlet installed by a qualified electrician Improper connection of the equipment 3 grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or p...

Page 6: ...U 95275 Do not use an adapter to connect this 9 compressor to a different outlet Symbology Double Insulated Canadian Standards Association Underwriters Laboratories Inc V Volts Alternating Current A Amperes n0 xxxx min No Load Revolutions per Minute RPM REV 10b ...

Page 7: ...g of this manual including all text under subheadings therein before set up or use of this product To prevent serious injury from accidental operation Turn the Switch OFF unplug the Compressor from its electrical outlet and release all air pressure from the air tank before assembling or making any adjustments to the compressor Note For additional information regarding the parts listed in the follo...

Page 8: ...r Tool 2 Connect a regulator valve an inline shut off valve and a 1 4 NPT air hose to the Quick Coupler The air hose must be long enough to reach the work area with enough extra length to allow free movement while working Note An in line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured The shutoff valve should be a ball valve beca...

Page 9: ...less all connections are air tight the extra air leaking out will cause the compressor to operate too often increasing wear on the compressor Note As long as the Switch is ON the operation of the Air Compressor is automatic controlled by an internal pressure switch The Compressor will turn on automatically when the air pressure drops to 85 PSI and will turn off automatically when the air pressure ...

Page 10: ...ose causing the b compressor to cycle too often and build up heat Correct any issues before further use to 3 avoid damage to the compressor Maintenance And Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician To prevent serious injury from accidental operation Turn the Switch OFF unplug the Compressor from its electrical outlet and release...

Page 11: ...rom the e compressor Monthly Inspect Safety Valve a To check for air leaks apply soapy water to joints while the Air Compressor is pressurized Look for air bubbles To clean the compressor surface wipe with a damp cloth using a mild detergent or mild solvent Draining Moisture from the Tank The Drain Valve is located under the Tank It must be accessed daily to release all trapped air and moisture fr...

Page 12: ...re Gauge for Extension Cords in Safety section Have unit inspected by a qualified technician 7 Compressor not building enough air pressure Compressor not large 1 enough for job Loose fittings 2 Hose or hose connections 3 not adequate High altitude reducing air 4 output Check Valve needs 5 service Check if accessory SCFM is met by Compressor If 1 Compressor cannot supply enough air flow SCFM you ne...

Page 13: ...ed Do not overtighten Moisture in discharge air Too much moisture in air Install inline air filter dryer and or relocate to less humid environment Safety Valve pops Safety valve needs service Pull on test ring of safety valve If it still pops replace Air leaking from fittings Loose fittings Reduce air pressure then check all fittings with a soap solution for air leaks and tighten as needed Do not ...

Page 14: ...4 Screw M6x25 4 45 Washer Lock 1 46 Screw M6x15 6 47 Screw ST4 8x15 1 48 Screw M5x25 2 49 Washer D5 2 50 Reset Button 4A Overload Protector 1 51 Nut Overload Protector 1 52 Wire Electric 1 53 Terminal Sheath 2 54 Terminal 2 55 Spring 1 56 Ball 1 57 O ring D14x1 8 1 58 Screw ST4 2x25 4 PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly d...

Page 15: ...U 95275 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts ASSEMBLY DIAGRAM ...

Page 16: ...al or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or pa...

Reviews: