background image

SKU 98635 

For technical questions, please call 1-800-444-3353. 

Page 4

dangerous in the hands of untrained 

users.

Maintain power tools.  Check for 

e. 

misalignment or binding of moving 

parts, breakage of parts and any 

other condition that may affect the 

power tool’s operation.  If dam-

aged, have the power tool repaired 

before use.

  Many accidents are 

caused by poorly maintained power 

tools.

use the power tool and acces-

f. 

sories in accordance with these 

instructions, taking into account 

the working conditions and the 

work to be performed.  

Use of the 

power tool for operations different 

from those intended could result in a 

hazardous situation.

Service

5. 

Have your power tool serviced by 

a. 

a qualified repair person using 

only identical replacement parts.  

This will ensure that the safety of the 

power tool is maintained.

Compressor Safety Warnings

Maintain labels and nameplates on 

1. 

the Compressor.  These carry impor-

tant safety information.  If unreadable 

or missing, contact Harbor Freight 

Tools for a replacement.
Avoid unintentional starting.  Prepare 

2. 

to begin work before turning on the 

Compressor.
Do not leave the Compressor unat-

3. 

tended when it is plugged into an 

electrical outlet.  Turn off the Com-

pressor, and unplug it from its electri-

cal outlet before leaving.

This product is not a toy.  Keep it out 

4. 

of reach of children.
People with pacemakers should 

5. 

consult their physician(s) before use.  

Electromagnetic fields in close prox

-

imity to heart pacemaker could cause 

pacemaker interference or pacemak-

er failure.  In addition, people with 

pacemakers should: 

• Avoid operating alone.

 

• Do not use with power switch locked 

on. 

• Properly maintain and inspect to 

avoid electrical shock. 

• Any power cord must be properly 

grounded.  Ground Fault Circuit Inter-

rupter (GFCI) should also be imple-

mented – it prevents sustained elec-

trical shock.
WARNING: Handling the cord on 

6. 

this product will expose you to lead, 

a chemical known to the State of 

California to cause cancer, and birth 

defects or other reproductive harm. 

Wash hands after handling.  (Califor-

nia Health & Safety Code §  25249.5, 

et seq.)
WARNING:  This product contains 

7. 

brass, which is a chemical known to 

the State of California to cause can-

cer and birth defects and other repro-

ductive harm.  (California Health & 

Safety Code § 25249.5, et seq.)
CAUTION:  Your Warranty is voided 

8. 

if:

You do not put compressor oil in the 

a. 

Compressor’s crankcase prior to its 

first use.  Before each use, check 

the oil level.  Never run the Com-

pressor with low or no compressor 

oil.  Running the Compressor with 

Summary of Contents for 98635

Page 1: ...served No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not...

Page 2: ...us situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address...

Page 3: ...off po sition before connecting to power source picking up or carrying the tool Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents...

Page 4: ...to an electrical outlet Turn off the Com pressor and unplug it from its electri cal outlet before leaving This product is not a toy Keep it out 4 of reach of children People with pacemakers should 5 c...

Page 5: ...d result Any tube pipe or hose used must have a pressure rating higher than 150 PSI Minimum recommended pipe size Up to 50 feet long use 1 2 diameter Greater than 50 feet use 3 4 diam eter Larger diam...

Page 6: ...d have a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resi...

Page 7: ...PSI Crankcase Oil Type SAE30 or L DAB 100 over 50 F SAE10 or L DAB 68 under 50 F Oil Capacity 8 5 ounces Unpacking When unpacking check to make sure that the item is intact and undamaged If any parts...

Page 8: ...ee Figure B Tool Air Compressor Quick Coupler Air Hose on Reel Filter Regulator with Pressure Gauge Male Connector Male Connector Valve Quick Coupler Attach an air hose to the Compres 7 sor s Quick Co...

Page 9: ...procedures Work Piece and Work Area Set Up Designate a work area that is clean 1 and well lit The work area must not allow access by children or pets to prevent injury and distraction Route the Power...

Page 10: ...aches the pneu 7 matic tool observe the Tool Pressure Gauge 64 Adjust the Regulator 62 to feed the proper PSI to the tool To do so turn the Regulator clockwise to increase PSI to the tool Turn the Reg...

Page 11: ...n two turns Then retighten the Drain Valve See Figure C Squeeze the trigger on the pneumatic 13 tool to release any remaining air pres sure from the tool Then disconnect the air hose from the tool and...

Page 12: ...Carefully unscrew no more than two turns the Drain Valve 53 until the compressed air and moisture begins to be discharged from the Tank Allow sufficient time for all of the air and moisture to escape...

Page 13: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 13 Power switch will not turn off Compressor 1 Defective power switch power switch...

Page 14: ...sher 5 47 Connecting Rod 14 Motor Stator 48 Capacitor 15 Motor Rotor 49 Wheel Assembly 16 Bearing 6203 50 Wheel Shaft Screw 17 Oil Seal 51 Wheel Shaft Sleeve 18 Crankcase 52 Hex Nut M8 19 Crank 53 Dra...

Page 15: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 15 ASSEMBLY DIAGRAM...

Page 16: ...of incidental or consequential damages so the above limita tion of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties...

Reviews: