background image

SKU 98635 

For technical questions, please call 1-800-444-3353. 

Page 9

position to prevent accidental opera-

tion.

note:

  Residual air pressure should not be 

present after the tool is disconnected 

from the air supply.  However, it is a 

good safety measure to attempt to 

discharge the tool in a safe fashion 

after disconnecting to ensure that the 

tool is disconnected and unpowered.

OPERAtInG InStRuCtIOnS

  Read the EntIRE IMPORtAnt 

SAFEtY InFORMAtIOn 

section at the beginning of this 

manual including all text under 

subheadings therein before set 

up or use of this product.

 

tO PREVEnt 

SERIOuS InjuRY 

FROM ACCIdEntAL 

OPERAtIOn: 

turn the Power Switch (60) of 

the Compressor to its “OFF” 

position and unplug the tool 

from its electrical outlet 

before performing any 

inspection, maintenance, or 

cleaning procedures.

Work Piece and Work Area Set up

Designate a work area that is clean 

1. 

and well-lit.  The work area must not 

allow access by children or pets to 

prevent injury and distraction.
Route the Power Cord (67) and air 

2. 

hose along a safe route to reach the 

work area without creating a tripping 

hazard or exposing the Power Cord 

or air hose to possible damage.  The 

Power Cord and air hose must reach 

the work area with enough extra 

length to allow free movement while 

working.
There must not be hazardous ob-

3. 

jects, such as utility lines or foreign 

objects, nearby that will present a 

hazard while working.
The Air Compressor should be po-

4. 

sitioned on a flat, hard surface and 

preferably in a dry location.

General Operating Instructions

Check to make sure the Compres-

1. 

sor’s Drain Valve (53), located at the 

bottom of the Tank (1) is fully closed. 

(See Figure C, next page.)

FIGuRE C

dRAIn VALVE

(53)

2.  Turn the Air Outlet Valve on the Reg-

ulator Assembly (62) to its “CLOSED” 

position.  

(See Figure d.)

Summary of Contents for 98635

Page 1: ...served No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not...

Page 2: ...us situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address...

Page 3: ...off po sition before connecting to power source picking up or carrying the tool Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents...

Page 4: ...to an electrical outlet Turn off the Com pressor and unplug it from its electri cal outlet before leaving This product is not a toy Keep it out 4 of reach of children People with pacemakers should 5 c...

Page 5: ...d result Any tube pipe or hose used must have a pressure rating higher than 150 PSI Minimum recommended pipe size Up to 50 feet long use 1 2 diameter Greater than 50 feet use 3 4 diam eter Larger diam...

Page 6: ...d have a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resi...

Page 7: ...PSI Crankcase Oil Type SAE30 or L DAB 100 over 50 F SAE10 or L DAB 68 under 50 F Oil Capacity 8 5 ounces Unpacking When unpacking check to make sure that the item is intact and undamaged If any parts...

Page 8: ...ee Figure B Tool Air Compressor Quick Coupler Air Hose on Reel Filter Regulator with Pressure Gauge Male Connector Male Connector Valve Quick Coupler Attach an air hose to the Compres 7 sor s Quick Co...

Page 9: ...procedures Work Piece and Work Area Set Up Designate a work area that is clean 1 and well lit The work area must not allow access by children or pets to prevent injury and distraction Route the Power...

Page 10: ...aches the pneu 7 matic tool observe the Tool Pressure Gauge 64 Adjust the Regulator 62 to feed the proper PSI to the tool To do so turn the Regulator clockwise to increase PSI to the tool Turn the Reg...

Page 11: ...n two turns Then retighten the Drain Valve See Figure C Squeeze the trigger on the pneumatic 13 tool to release any remaining air pres sure from the tool Then disconnect the air hose from the tool and...

Page 12: ...Carefully unscrew no more than two turns the Drain Valve 53 until the compressed air and moisture begins to be discharged from the Tank Allow sufficient time for all of the air and moisture to escape...

Page 13: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 13 Power switch will not turn off Compressor 1 Defective power switch power switch...

Page 14: ...sher 5 47 Connecting Rod 14 Motor Stator 48 Capacitor 15 Motor Rotor 49 Wheel Assembly 16 Bearing 6203 50 Wheel Shaft Screw 17 Oil Seal 51 Wheel Shaft Sleeve 18 Crankcase 52 Hex Nut M8 19 Crank 53 Dra...

Page 15: ...SKU 98635 For technical questions please call 1 800 444 3353 Page 15 ASSEMBLY DIAGRAM...

Page 16: ...of incidental or consequential damages so the above limita tion of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties...

Reviews: