Page 6
SKU 47407
for technical questions, please call 1-800-444-3353.
empty air and Condensation
The water spill valve Petcock (11) is located underneath the Air Tank (shown in the photo
on page 4). It must be used daily to release all trapped moisture from the tank. It will also
get rid of any condensation that may cause tank corrosion.
warning: do not open the water Spill Valve so that more than four threads are show-
ing.
1.
Push the On/Off Switch to turn the compressor off.
2.
Unscrew the water spill valve Petcock (11) two to three turns only.
3.
When all pressure is released, close the water spill valve again.
maintenance
1.
Purge the Air Tank daily of all air and moisture to prevent corrosion.
2.
Store the Air Compressor in a clean and dry location.
3.
Check all air fittings for leaks before using.
PleaSe read tHe followInG Carefully
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS
MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBU-
TOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE
IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE
BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING