background image

Page 2

SKU 95499

for technical questions, please call 1-800-444-3353.

07b, 07e; 09g

SPECIfICAtIONS

Electrical Requirements 120 V~ / 60 Hz / 2 HP Motor / 3400 RPM

14 Rated Amps
Power Cord Type: 14 AWG x 3 C x 6’10-1/2” Long
Power Plug Type: 3 Prong Grounded
Pressure Switch Type: ON/OFF (Pull/Push)

Compressor Style

Pancake Round Tank

Pump Style

Single Cylinder

Maximum Air Pressure

115 PSI

Air Flow Capacity

5.8 SCFM @ 40 PSI
4.4 SCFM @ 90 PSI

Auto Turn On/Shut Off

Pressure On @ 85 PSI / Pressure Off @ 115 PSI

Air Tank Capacity

4 Gallons

Air Outlet Size

1/4”-18 NPT Female Threads

Recommended Oil Type SAE 15W-30W Non-Detergent Compressor Oil 
Overall Dimensions

15-3/4” Diameter x 21” High

Weight

50 lb.

SAVE tHIS MANuAL

You will need this manual for the safety warnings and precautions, assembly, oper-

ating, inspection, maintenance and cleaning procedures, parts list and assembly diagram.  
Keep your invoice with this manual.  Write the invoice number on the inside of the front 
cover.  Keep this manual and invoice in a safe and dry place for future reference.

GENERAL SAfEty RuLES ANd PRECAutIONS

WARNING!

REAd ANd uNdERStANd ALL INStRuCtIONS

failure to follow all instructions listed below may result in 

electric shock, fire, and/or serious injury.

SAVE tHESE INStRuCtIONS

WORK AREA

Keep your work area clean and well lit.  

1. 

Cluttered benches and dark areas invite 

accidents.

do not operate air compressors in explosive atmospheres, such as in the 

2. 

presence of flammable liquids, gases, or dust.  Air Compressors create sparks 
which may ignite the dust or fumes.

Keep bystanders, children, and visitors away while operating an air tool.  

3. 

Dis-

tractions can cause you to lose control.  Protect others in the work area from debris 
such as chips and sparks.  Provide barriers or shields as needed.  Children should 
not be allowed in the work area.

Summary of Contents for CENTRAL PNEUMATIC 95499

Page 1: ...our website at http www harborfreight com To prevent serious injury read and understand all warnings and instructions before use Copyright 2007 by Harbor Freight Tools All rights reserved No portion o...

Page 2: ...enance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and d...

Page 3: ...ter control of the air tool in unexpected situations Use safety equipment Always wear eye protection 6 Always wear ANSI approved safety impact glasses and hearing protection under a full face shield d...

Page 4: ...ble in line safety and alarm equip ment not included This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in C...

Page 5: ...unattended when it is plugged in and running 14 Turn off the Compressor and unplug the unit before leaving Do not allow children and other unauthorized people to handle or play with 15 the Air Compres...

Page 6: ...g Required have a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electri cally malfunction or break down grounding pro vides...

Page 7: ...boratories Inc V Volts Alternating Current A Amperes n0 xxxx min No Load Revolutions per Minute RPM UNPACKING When unpacking check to make sure all the parts shown on the Parts List on page 13 are inc...

Page 8: ...r tools and equipment it is recommended that you install an oiler and water filter in line with the Air Outlet Valve 67 of the Air Compressor See Figure C Prior to using the Air Compressor the unit 3...

Page 9: ...SIGHT GLASS 21 OIL BREATHER CAP 24 FIGURE E Desired Level 2 To do so unscrew and remove the Oil Breather Cap 24 Pour approximately 1 2 quart of compressor oil into the Oil Breather Cap hole Do not ov...

Page 10: ...ic tool not included that is to be used See Figure F next page Plug the Power Cord 55 into the nearest 120 volt grounded electrical outlet 4 Pull 5 up on the Pressure Switch 63 to its START position t...

Page 11: ...Switch 63 of the Air Compressor is in its STOP position and the unit is unplugged from its electrical outlet before perform ing any inspection maintenance or cleaning procedures or leaving it unattend...

Page 12: ...e 1 Compressor overheated 2 Restricted oil breather cap 3 Drain crankcase and refill to proper level on 1 sight glass Reduce air pressure regulation 2 Clean or replace oil breather cap 3 Pressure swit...

Page 13: ...and 19 Crankcase Gasket 20 Crankcase Cover 21 Oil Sight Glass 22 Hex Head Screw 23 Pan Head Screw M6 x 14 Part Description 24 Oil Breather Cap 25 Spring Washer 8 26 Washer 8 27 Screw M8 x 20 28 Connec...

Page 14: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may...

Reviews: