background image

Carefully read the precautions and follow the procedures correctly.

WARNING! 

Do not try to install the stove;

 

Always contact authorized and trained personnel.

- In case of breakage or poor functioning always contact the Authorized Assistance Centre; 

any attempt to remove parts or perform maintenance on the device can expose the user to electrical 
shock danger. The stove contains parts whose maintenance must be done by the Authorized Assistance 
Centre.

- The stove is a heating device; 

its parts reach extreme temperatures and contact without adequate 

protection can provoke burns of various degrees. 

  Pay particular attention to children.

- In case of a transfer, contact the Authorized Assistance Centre for the removal and new installation.
- Do not insert fingers or other objects in the air flow exit slits. 

Inside the device there is a high speed fan that could cause grave personal injury. Pay particular attention 
to children.

- Do not remain for long periods directly exposed to the flow of hot air.

Direct and prolonged exposition to the cold air could be hazardous to health. Pay particular attention in 
rooms where there are children, the elderly or the ill.

- In case the stove functions poorly, shut down the device immediately, unhook the appropriate 

automatic switch and contact the Authorized Assistance Centre.  

The continued use of the device 

in said conditions can cause fires or flashes.

- If you do not use the auxiliary air outlet (only for models with canalisation), check that the fan speed is set 

on zero (deactivated).

WARNING!  

- During the stove installation operation, keep children out of the work area to avoid unforeseen 

accidents.

-  Do not block or cover in any way the body of the stove or obstruct the slits placed on the upper 

side.

 

Obstructing said slits can cause fires.

-  Do not use the stove in areas containing precision devices or works of art.

The quality of the conserved objects may deteriorate.

-  Do not expose animals or plants to direct air flow from the unit.

Prolonged direct exposition to the flow of air from the stove can have negative effects on plants and 

animals.

-  Occasionally ventilate the room during the use of the device.

Insufficient ventilation can be the origin of insufficient oxygen in the room.

-  Do not expose the stove to contact with water.

The  electrical  insulation  could  be  damaged,  with  the  consequent  possibilities  of  electrocution  and 

breakage due to the thermal extremes.

-  Verify the installation conditions to locate eventual damage.

After the stove has completed 900 hours of operation (the lower screen will read “SErV”), contact the 

Authorized Assistance Centre for cleaning and ordinary maintenance.

-  Do not use inflammable gas near the stove.

-  Unhook the automatic switch if the device will not be used for long periods of time.

We check the start up of all our stoves.

Summary of Contents for CentroPelet ZS10

Page 1: ...let ZS10 TUZS10ENG 4 2014 HR Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 for installation use and maintenance of pellet stove TECHNICAL INSTRUCTIONS HEATING TECHNIQUE ...

Page 2: ...ance Centre The continued use of the device in said conditions can cause fires or flashes If you do not use the auxiliary air outlet only for models with canalisation check that the fan speed is set on zero deactivated WARNING During the stove installation operation keep children out of the work area to avoid unforeseen accidents Do not block or cover in any way the body of the stove or obstruct t...

Page 3: ...intenance Failure to observe the instructions contained in the manuals Use in non conformity with the safety directives Installation in non conformity with the norms in force in the country Installation by unqualified or untrained personnel Modifications and repairs not authorized by the manufacturer Use of non original replacement parts Exceptional events Use of pellets not approved by the manufa...

Page 4: ... feeding channels or tubes for electrical system usage through the flue even if oversized It is advisable that the flue be furnished with a chamber which collects solid material and eventual condensation situated below the vertical entrance to the flue so that it is easily opened and inspected through the air tight door Whenever flues with parallel exits are used it is advisable to raise the upwin...

Page 5: ... and an environmental well being Be sure that the room where the stove is installed has sufficient aeration and if necessary install an air intake duct with a minimum recommended diameter of 50 mm to bring in air from the outside The external air intake must communicate with the stove and positioned so that it is not obstructed It must be protected with a permanent non closable grill or other suit...

Page 6: ...per campi di dimensioni nominali secondo UNI ISO 2768 Designa zione Denominazione da 0 5 fino 3 oltre 3 fino 6 oltre 6 fino 30 oltre 30 fino 120 oltre 120 fino 400 oltre 400 fino 1000 oltre 1000 fino 2000 oltre 2000 fino 4000 1 1 1 30 3 0 30 0 30 1 2 0 20 0 20 0 30 1 0 10 0 10 0 15 0 30 0 5 0 5 0 10 0 20 fine media grossolana molto grossolana Scostamenti limite in funzione dei campi di lunghezza i...

Page 7: ...ction is obligatory if the cable issued with the stove is not long enough to reach the closet socket use an extension cable along the floor Fire Safety Distance The stove must be installed respecting the following safety conditions Minimum distance from the sides and the back must be 40 cm from moderately inflammable material Easily inflammable material must not be place closer than 80 cm in front...

Page 8: ...rect and safe placement of the air intake all the measures and prescriptions Fig 7 must be respected There are distances to respect to prevent the comburant air from being subtracted from another source for example the opening of a window could cause eddies in the outside air subtracting it from the stove Fig 7 distance from walls 5 cm ...

Page 9: ...y connect the pellet stove to the flue Fill the tank with 6mm diameter pellets Open the door and check that the basket is properly inserted in its slot and that the flame trap is located in the upper part of the combustion chamber Close the door Never open the door while the pellet stove is operating Connect the stove to an outlet with the appropriate cable received with the stove Place the switch...

Page 10: ... the residual smoke Pictures are indicative and can differ from the original product Pictures are an example to understand how the product works Operations to be performed by the Authorized Assistance Centre every season before the lighting A general cleaning inside and outside A careful cleaning of the exchange tubes A careful cleaning and disincrustation of the crucible and the relative cavity C...

Page 11: ...GB Notes ...

Page 12: ...ors or error made in transcription and all figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE ...

Reviews: