GB

Positioning

The stove is furnished with an electrical cable 

to connect to a 230V 50Hz socket, preferably 
with a thermal-magnetic switch. Variations in 
tension of more than 10% can compromise 
the stove (if not already present, an adequate 
differential switch should be provided).

The  electrical  system  must  comply  with  the 

norms; verify in particular the efficiency of 
the ground circuit. The electrical feed cable 
must be of a diameter adequate to the power 
of the device.

The stove must be completely level. Verify the 

weight bearing capacity of the flooring.

The  placement  of  the  stove  within  the  living 

environment is determined so that the 
environment is heated in a uniform manner. 
Before deciding where to place the stove, 
keep in mind that:

• The air used for combustion must not come

from a garage or a space without ventilation 
or air exchange, but from a free space or the 
outside;

• The  stove  should  not  be  installed  in  a

bedroom;

• Rather it is preferable to install the stove in a

large, central room of the house to insure the 
maximum heat circulation;

• A grounded electrical connection is obligatory

(if the cable issued with the stove is not long 
enough to reach the closet socket, use an 
extension cable along the floor).

Fire Safety Distance

The  stove  must  be  installed  respecting  the 

following safety conditions:

• Minimum  distance  from  the  sides  and  the

back  must  be  40  cm  from  moderately 
inflammable material;

• Easily inflammable material must not be place

closer than 80 cm in front of the stove;

• If  the  stove  is  installed  on  an  inflammable

pavement the stove must be placed on a 
slab of material that insulates it from the heat 
that is wider at the sides by 20 cm and in the 
front by 40 cm;

• Do not place objects in inflammable material

or any material that can compromise the 
operation of the stove on the stove or within 
the safety distance;

• In  addition,  it  is  advisable  to  keep  all

elements of combustible or inflammable 
material such as beams, wooden furniture, 
drapes, inflammable liquids, etc. outside the 
radiance area of the stove, and in any case 
at least 1 m from the heating block (Fig. 6);

• In  case  of  connection  to  wooden  walls  or

other inflammable material, it is necessary 
to insulate the smoke discharge tube with 
ceramic fibre or another material with the 
same characteristics.

Fig. 6: minimum distance of objects

40 cm

20 cm

20 cm

40 cm

5/7 cm

40 cm

80 cm

Summary of Contents for CentroPelet ZS10

Page 1: ...let ZS10 TUZS10ENG 4 2014 HR Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 for installation use and maintenance of pellet stove TECHNICAL INSTRUCTIONS HEATING TECHNIQUE ...

Page 2: ...ance Centre The continued use of the device in said conditions can cause fires or flashes If you do not use the auxiliary air outlet only for models with canalisation check that the fan speed is set on zero deactivated WARNING During the stove installation operation keep children out of the work area to avoid unforeseen accidents Do not block or cover in any way the body of the stove or obstruct t...

Page 3: ...intenance Failure to observe the instructions contained in the manuals Use in non conformity with the safety directives Installation in non conformity with the norms in force in the country Installation by unqualified or untrained personnel Modifications and repairs not authorized by the manufacturer Use of non original replacement parts Exceptional events Use of pellets not approved by the manufa...

Page 4: ... feeding channels or tubes for electrical system usage through the flue even if oversized It is advisable that the flue be furnished with a chamber which collects solid material and eventual condensation situated below the vertical entrance to the flue so that it is easily opened and inspected through the air tight door Whenever flues with parallel exits are used it is advisable to raise the upwin...

Page 5: ... and an environmental well being Be sure that the room where the stove is installed has sufficient aeration and if necessary install an air intake duct with a minimum recommended diameter of 50 mm to bring in air from the outside The external air intake must communicate with the stove and positioned so that it is not obstructed It must be protected with a permanent non closable grill or other suit...

Page 6: ...per campi di dimensioni nominali secondo UNI ISO 2768 Designa zione Denominazione da 0 5 fino 3 oltre 3 fino 6 oltre 6 fino 30 oltre 30 fino 120 oltre 120 fino 400 oltre 400 fino 1000 oltre 1000 fino 2000 oltre 2000 fino 4000 1 1 1 30 3 0 30 0 30 1 2 0 20 0 20 0 30 1 0 10 0 10 0 15 0 30 0 5 0 5 0 10 0 20 fine media grossolana molto grossolana Scostamenti limite in funzione dei campi di lunghezza i...

Page 7: ...ction is obligatory if the cable issued with the stove is not long enough to reach the closet socket use an extension cable along the floor Fire Safety Distance The stove must be installed respecting the following safety conditions Minimum distance from the sides and the back must be 40 cm from moderately inflammable material Easily inflammable material must not be place closer than 80 cm in front...

Page 8: ...rect and safe placement of the air intake all the measures and prescriptions Fig 7 must be respected There are distances to respect to prevent the comburant air from being subtracted from another source for example the opening of a window could cause eddies in the outside air subtracting it from the stove Fig 7 distance from walls 5 cm ...

Page 9: ...y connect the pellet stove to the flue Fill the tank with 6mm diameter pellets Open the door and check that the basket is properly inserted in its slot and that the flame trap is located in the upper part of the combustion chamber Close the door Never open the door while the pellet stove is operating Connect the stove to an outlet with the appropriate cable received with the stove Place the switch...

Page 10: ... the residual smoke Pictures are indicative and can differ from the original product Pictures are an example to understand how the product works Operations to be performed by the Authorized Assistance Centre every season before the lighting A general cleaning inside and outside A careful cleaning of the exchange tubes A careful cleaning and disincrustation of the crucible and the relative cavity C...

Page 11: ...GB Notes ...

Page 12: ...ors or error made in transcription and all figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE ...

Reviews: