10
4 Mounting process
1 - Removing roof tiles
Select the first rafter from the left for mounting
the first roof hook using the rafter configuration
plan and taking account of the margins and the
maximum cantilevers to be observed.
Remove the roof tiles above the rafter to be al-
located.
It may be necessary to remove several roof tiles
from the system in order to carry out the mount-
ing depending on the individual rafter distances.
Note:
Each rafter must be allocated when using
a CENPAC including the wind and snow exten-
sion package. Please observe the assembly in-
structions of the extension package.
2a - Positioning of the roof hook
The roof hooks can now be mounted onto the
cleared rafters. When positioning the base of
the roof hook, ensure that it lies flat on the rafter.
Please ensure:
The roof support shaft (a) may
not lie directly on the tile.
2b - Positioning of the roof hook
The roof hooks are tailored to
battens 30 x 50
mm. A batten 40 x 60 mm requires the installa
-
tion of separators, e.g., of 10 mm thick impreg
-
nated wood. (b)
a
b
a