E1200 HT 260-3
2BSafety
23.04.07
00401010_41087
3-5
Safety Device
Function
loading box door (option)
Screening of potentially dangerous movements of the
drives. All mechanical movements are stopped as soon
as a protective door is opened. Protection for persons
and property.
protective grating in the
inspection window of
PECVD systems (option)
Protection for persons and property.
scanner slider PECVD-
equipment (option)
Controls the area around the slider during manual
loading. Stops the movement of lift and slider, if persons
or objects are in the area. Protection for persons and
property.
power control unit for the
glow plug of the flaring unit
(option)
Monitors the glow plug. Ensures that H
2
is burned in the
flaring unit. Closes H
2
valve as soon as errors occur.
Protection for persons and property.
flame monitoring hydrogen
(option)
Monitors the glow plug. Ensures that H
2
is burned in the
flaring unit. Closes H
2
valve as soon as errors occur.
Protection for persons and property.
ratio monitoring (RACON)
for bubbler system (option),
forming gas system (option)
and synthesis steam
generator (option)
Monitors two independent gas flows and closes the valve
of the monitored gases in case of disturbance. Protection
for persons and property.
flame monitoring within the
synthesis steam generator
(option)
Monitors the H
2
flame of the synthesis steam generator.
Closes H
2
valve as soon as errors occur. Protection for
persons and property.
temperature monitoring of
synthesis steam generator
(option)
Monitors the temperature of the synthesis steam
generator. The H
2
valve does not open if the temperature
is too low. The H
2
valve closes if the temperature
decreases too much. Protection for persons and
property.
temperature monitoring of
the synthesis steam
generator cooling water
(option)
Monitors the temperature of the cooling water. The H
2
valve closes if the temperature is too high. Protection for
persons and property.
temperature monitoring of
the DCE bubbler
Monitors the temperature of the DCE bubbler. If the
temperature is outside the tolerance range, an acoustic
signal is output. System protection.
filling level monitoring of the
DCE bubbler
Monitors the DCE bubbler fluid level. If the fluid level is
too low, an acoustic signal is output. System protection.
Table 3-1:
Safety Devices
Summary of Contents for E1200 HT 260-3
Page 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Page 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Page 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Page 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Page 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Page 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Page 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Page 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Page 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Page 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Page 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Page 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...