Fill in data for later reference

AUTOCLOSE TIME

All

PED. AUTOCLOSE TIME

All

COURTESY LIGHT TIME

All

AUTOCLOSE OVER-RIDE 

All

PRE-FLASH TIME

All

COLLISION COUNT

All

CRAWL DISTANCE (1 FLASH = 350mm)

D3/D5

AUTOCLOSE ON

ON

OFF

All

MODE

Standard

Condominium

PIRAC

Reversing

PLC (A10 only)

All

COLLISION SENSITIVITY

High

Medium

Low

All

POSITIVE CLOSE MODE

YES

NO

All

PRE-FLASHING MODE

1
2
3

OFF

All

Default

Actual

Model:

Quick Ref.

L.E.D.

Page 27

General commissioning

check sheet

General commissioning

check sheet

Standard speed

Standard speed + 30%
Standard speed + 60%
Standard speed + 90% 

A10

OPENING SPRINT MODE SELECT: 

15 Secs

3/Time

5 Secs

5/Time

120 Secs

6/Time

3 Secs

8/Time

5 Secs

11/Time

4

12/Count

350mm

13/Count

OFF

2/1
2/2

Standard

4/1
4/2
4/3
4/4
4/5

Medium

7/1
7/2
7/3

NO

9/1
9/2

OFF

10/1
10/2
10/3
10/4

Standard

13/1
13/2
13/3
13/4

Summary of Contents for A10

Page 1: ...D3 D5 and A10 User guide TM TM TM DOMESTIC AND INDUSTRIAL SLIDING GATE OPERATORS ...

Page 2: ...paired by any workshop and or person NOT previously authorised by Centurion Systems Pty Ltd e Has been repaired with components not previously tested passed or authorised by Centurion Systems Pty Ltd All CENTSYS products are manufactured with extreme care thoroughly inspected and tested The products are only guaranteed against faulty materials or workmanship for a period of 12 months from the invo...

Page 3: ...cians and sales personnel together with a fully fledged in house training facility we are committed to providing unmatched service to our customers and support for our products A worldwide network of distributors and installers ensure that our products remain The Automatic Choice in access automation Further information is available on our website www centsys com au CENTURION SYSTEMS PTY LTD 2005 ...

Page 4: ...attery low protection 12 Thermal overload 12 Origin sensor fail 13 Lightning protection 13 Ancillary equipment 13 Protection beam 13 Holiday lockout 14 Courtesy light timer 14 Pre flashing 14 Gate status indication 15 Solar panel 15 DC Converter module 16 Reversing mode 18 Condominium 18 Passive infraRed Autoclose PIRAC 18 Manual release 19 Re engaging the manual release 20 Page 4 Table of Content...

Page 5: ...ox oil level 21 Power supply 21 A10 Inverter module 22 Specifications 23 D3 D5 Operator 23 A10 Operator 24 A10 DC Converter 24 Optional extras 25 Declaration of Conformity 26 Commissioning check sheet Page 5 20 20 21 21 21 22 23 23 24 24 25 26 27 28 ...

Page 6: ...of the CENTSYS range of operators is the limit switch mechanism Mounted internally and therefore tamper proof the limit switch monitors the speed and location of the gate ensuring reliable and safe anti crushing protection and accurate position control Precise control of the gate stopping position is achieved by a high resolution encoder wheel and opto electronic sensor built into the unit The ele...

Page 7: ... and uses the same technology in terms of origin and encoder signal inputs Unique to the A10 is the high speed mode enabling adjustable opening and closing speeds up to 30 metres per minute The key to the A10 s outstanding torque and duty cycle lies in the three phase induction motor and electronic inverter that form the heart of the system Single phase 220 240V AC power is converted into variable...

Page 8: ...stop Pressing the button again will cause the gate to reverse If the automatic closing feature see Controller Features and Functions has been selected and the gate is closing automatically when the transmitter is pressed the gate will stop and stay in that position Pressing the button again will cause the gate to re open If the gate is opening with the automatic closing facility selected and the t...

Page 9: ...witch As soon as the key is released back to its normal rest position the gate will close after the five second delay The opening distance and the time that the gate remains open can be adjusted to suit Default values are described above If a protection beam has been fitted refer section Protection Beams and the beam is broken while the gate is closing the gate will stop The gate will remain in th...

Page 10: ...ening Gate stops on hitting the obstruction Page 10 STOP If the gate is obstructed repeatedly four times either opening or closing often referred to as multiple collision the gate will stop and will not respond to trigger inputs for two minutes After this time the gate will once again respond to command signals This function is a warning to the user that the obstruction must be removed The number ...

Page 11: ... The system has the facility to automatically close the gate after it has been opened The default setting is that this facility is disabled The time that the gate remains open can be adjusted up to four minutes where the default is 15 seconds The Autoclose function can be temporarily overridden by holding down the remote control pushbutton or intercom gate release when opening the gate until the g...

Page 12: ...m the battery but not replaced To prevent the battery running flat and being damaged the protection circuitry shuts off the gate system when the battery voltage drops below 10 6V Mains failure detection D3 D5 only Battery low protection D3 D5 only RED LED STATUS NOTE LED WILL FLASH THREE TIMES EVERY TWO SECONDS TO INDICATE BATTERY VOLTAGE IS LOW D3 D5 OPERATOR PCB SHOWN If the gate status indicato...

Page 13: ...to the user that there has been an origin sensor failure the status LED will flash three times every two seconds This condition is treated as serious and the unit cannot be activated again until the gate has been moved manually either fully open or fully closed ensuring that the gate magnet has passed the sensor If the sensor registers correctly the unit will reset and can be operated again If the...

Page 14: ...ements A courtesy light pushbutton can be mounted inside the house typically on the intercom allowing convenient control of the lights By pressing the pushbutton By pressing the courtesy light pushbutton if fitted momentarily the light will switch on for the light timer period and automatically switch off By pressing and holding the pushbutton down for three seconds the lights will switch on and r...

Page 15: ... crushing Device page 11 Mains failure D3 D5 only See Mains Failure Detection page 13 Courtesy light switched on see Courtesy Light Timer page 15 Gate is closing Or Or Over temperature A10 only See Thermal Overload page 14 Page 15 Gate status indication optional The controller can provide visual indication inside the house of the position of the gate and the condition of the battery and power supp...

Page 16: ...r to function from a 12V battery in the absence of AC mains The converter module steps up the 12V battery supply to 310V DC The inverter drive on the A10 operator then switches the high voltage DC supply to run the three phase induction motor The converter module includes battery protection circuitry This circuitry prevents the converter module from being damaged in the event of reverse polarity c...

Page 17: ...rter The LEDs operate in the following manner The converter module has a current limiting fuse on the high voltage supply Caution must be exercised when checking this fuse The procedure to replace the fuse is outlined below 1 Disconnect the mains from the entire system This includes the A10 and the converter module 2 Disconnect the battery 3 Disconnect the six way header that connects the converte...

Page 18: ...shbutton is pressed while the gate is open the Autoclose will restart its countdown If the gate is activated while the gate is closing the gate will reopen The gate cannot be stopped in a midway position and will therefore always close A protection beam should be used in conjunction with this facility to prevent the Autoclose from closing the gate onto a vehicle passing through This facility is an...

Page 19: ...release mechanism This is to allow the gate to be operated in the event of a total malfunction of the equipment It is also required if the mains power has failed in the case of the A10 without DC converter operator Rotate thumbwheel clockwise until gate is free to move Manual release handle in closed position Open lock cover and insert key Turn key turn counter clockwise to unlock Pull manual rele...

Page 20: ...ecessary to replace these components regularly Ensure that the rack is properly secured to the gate and that it does not press down onto the operator pinion at any point along its travel Keep shrubs and vegetation clear of the motor rack or chain Check that the key still operates the manual override access door or flap Spray with oil if necessary Keep the inside of the motor housing clear of insec...

Page 21: ...section Lubrication of the Installation Manual Should the installation manual be unavailable please refer to the Online Manuals on our website www centsys com au Alternatively please contact your CENTSYS installer All Centurion Systems Pty Ltd operators have power supplies separate to the controllers In the case of product malfunction the power supply fuses should be checked NOTE D5 D3 OPERATOR PC...

Page 22: ...OLLED SWITCH FOR COURTESY LIGHT FUSE 3 3A FAST BLOW FUSE 2 50mA SLOW BLOW FUSE 1 5A FAST BLOW Page 22 A10 models are supplied with spare fuses housed in the controller card cover Be careful to replace A10 fuses with those of the correct rating see diagram below The small green light LED on the controller marked POWER indicates if the card is active Each power supply has a red light LED to indicate...

Page 23: ...ttery Half day 20 61 Battery driven 1A charge 7Ah battery Battery driven 2A charger 7Ah battery Power pack 10A power pack no battery 10 30 20 10 N A N A Battery driven 1A charger 7Ah battery Battery driven 2A charger 7Ah battery Power pack 10A power pack no battery 20 N A N A 50 150 100 Maximum gate mass 300kg 500kg Rated pull force 12kgF 20kgF Starting pull force 20kgF 30kgF Output shaft rotation...

Page 24: ... 6kg 40kgF 30kgF 30kgF 22 5KgF 6A 220 240V three phase 20 Tooth Mod 4 2 Adj Up to 30m min 16m min High Efficiency Fan 2300 RPM 90 95 O O 20 C to 50 C Electronic Electronic 20m 44 Yes 15 7kg 1 000kg 600kg 2 000kg Maximum gate mass SPECIFICATIONS Input voltage Input current rated thrust Rated output voltage Battery charger Maximum duty cycle Thermal protection Enclosure Dimensions Maximum battery si...

Page 25: ...tional extras Optional extras Access control proximity unit Access control keypad Safety beams A10 Theft resistant cage D3 D5 Theft resistant cage Intercom 2 3 1 abc 3 Efg 4 Hij 5 klm 6 nop 7 qrs 8 tuv 9 wxvz 10 ...

Page 26: ...000 3 2 1997 IEC 1000 3 3 1997 IEC 1000 4 5 1997 IEC 61000 4 2 ELECTROSTATIC DISCHARGE IEC 61000 4 3 RADIATED IMMUNITY 80MHZ TO 1000MHZ IEC 61000 4 4 ELECTRICAL FAST TRANSIENTS BURST IEC 61000 4 5 SURGE IMMUNITY TEST IEC 61000 4 6 CONDUCTED IMMUNITY 150KHZ TO 80MHZ IEC 61000 4 11 VOLTAGE DIPS AND INTERRUPTION Supply Information The product herewith complies with the requirements fo the following d...

Page 27: ...ium Low All POSITIVE CLOSE MODE YES NO All PRE FLASHING MODE 1 2 3 OFF All Default Actual Model Quick Ref L E D Page 27 General commissioning check sheet General commissioning check sheet Standard speed Standard speed 30 Standard speed 60 Standard speed 90 A10 OPENING SPRINT MODE SELECT 15 Secs 3 Time 5 Secs 5 Time 120 Secs 6 Time 3 Secs 8 Time 5 Secs 11 Time 4 12 Count 350mm 13 Count OFF 2 1 2 2 ...

Page 28: ...EDGES FITTED TO ALL HAZARDOUS EDGES D3 D5 OPERATORS INSTALLED WITH CE CHIP FITTED TO CONTROLLER COLLISION SENSITIVITY see above SET TO HIGH OR MEDIUM CE Compliance The following checks must be made in addition to the above checks to ensure a CE compliant installation Standard speed Standard speed 30 Standard speed 60 Standard speed 90 CLOSING SPRINT MODE SELECT Standard A10 14 1 14 2 14 3 14 4 Pag...

Page 29: ...Notes Notes ...

Page 30: ...Notes Notes ...

Page 31: ...Notes Notes ...

Page 32: ...www centsys com au 0 07 B 0031 D3 D5 and A10 User guide 10Jul2012 ...

Reviews: