page 8
Based on 4m gate, no accessories fitted, such as infrared beams
Fuse protection
The following protection fuses are provided on the system:
Item
Type
Rating
Main controller
Motor circuit
Automotive fuse ATO (25 x 7mm) 30A
Light circuit
5 x 20mm
3A fast blow
Auxiliary supply
Resettable fuse
3A
Charger
Mains input
5 x 20mm
3A fast blow*
*Not user serviceable
4. Icons used in this manual
This icon indicates tips and other
information that could be useful
during the installation.
This icon indicates warning, caution or attention! Please take special note of critical
aspects that MUST be adhered to in order to prevent injury.
This icon denotes variations and other
aspects that should be considered
during installation.
Duty cycle - mains present
Operations in standby with 7Ah battery
half day
full day
Operations in standby with 35Ah battery
half day
full day
Collision sensing
Operating temperature range
Onboard receiver type
Receiver code storage capacity
Receiver frequency
Mass of unit packed (standard kit, excl.
rack and battery)
Packing dimensions (standard kit, excl.
rack and battery)
50%
44
35
150*
150*
electronic
-15°C to +50°C
CENTSYS code-hopping multichannel
500 transmitter buttons
433MHz
10kg
231mm deep x 303mm wide x 432mm high
Limited by maximum daily usage
Based on a push force of less than 50% of rated