18. Commissioning the system
Setting the gate limits
1. Disengage the manual release lever,
ensuring that the origin marker is
correctly fitted.
Move the gate to the middle of travel and
re-engage the manual release lever.
page 35
FIGURE 49
FIGURE 48
*For more details about the Profile (operating standard), refer to Section 22,
Factory defaults schedule
2. a) If powering up the system ex-factory,
it will request for the operating
Profile*
(operating standard) to be set.
ZA: Standard profile for South Africa
CE: Standard profile for the European
Union
UL325: Standard profile for the USA
b) Select the
Profile
that will suit the
specific region from the list. With this
set, the system will automatically
proceed to the limit setup menu. Follow
the onscreen instructions to complete the
setup procedure
c) If powering up at any stage after this,
push and hold the oblong
enter
button
( ) for two seconds.
Select the “limits” menu by pressing the
enter
button ( ). Follow the
onscreen instructions to complete the
setup procedure.