page 42
Menu 5 - Run profile
Positive Close Mode (PCM)
Setting Positive Close Mode to
on
will allow the gate to drive up hard to the
closed endstop without causing the collision circuitry to operate. This feature
operates only during the last few millimeters of gate travel in closing mode.
PCM push force
The amount of force applied by the motor when in PCM can be set as a
percentage of full motor force.
Pre-open delay
Allows a delay between a valid trigger signal being received and the gate
commencing movement in the opening direction. A warning light can be set to
activate during this delay. (Refer to pre-flash modes of the
pillar light
feature,
for more details).
Pre-close delay
Allows a delay between a valid trigger signal being received and the gate
commencing movement in the closing direction. The delay will also occur if the
gate is set to close automatically. A warning light can be set to activate during
this delay. (Refer to pre-flash modes of the
pillar light
feature, for more
details).
Opening speed
Sets the maximum opening speed in metres per minute. This can be set from
10 to 22 metres per minute. Selecting maximum will move gate at maximum
possible speed.
Closing speed
Sets the maximum closing speed in metres per minute. This can be set from
10 to 22 metres per minute. Selecting maximum will move the gate at
maximum possible speed.
Ramp-up distance
Sets the ramp-up distance in centimetres of travel of the gate when starting.
This can be set from 10 centimetres to 10 metres in 1 centimetre steps.
Ramp-down distance
Sets the ramp-down distance in centimetres of travel of the gate when
stopping. This can be set from 10 centimetres to 10 metres in 1 centimetre
steps.
TRG stop distance
Sets the distance over which a moving gate will stop after a Trg input is
received. This can be set from 10 centimetres to 1 metre in 1 centimetre
steps.
Deadman Control Mode (DMC)
A permanent trigger on FRX (NO) will cause the gate to open. Removing
the trigger will cause the gate to stop
A permanent trigger on Trg (NO) will cause the gate to close. Removing
the trigger will cause the gate to stop
A permanent trigger on Lck/Stp (NC) will stop a moving gate, and prevent
a stationary gate from moving
IRB stop distance
Sets the distance over which a moving gate will stop after an
infrared safety
beam
is broken. This can be set from 10 centimetres to 1 metre in 1
centimetre steps.