6.4 FRX (Free-exit) loop direction
Allows a single access point with bi-directional traffic to make use of a free-exit
loop. Due consideration must be given to closing and free-exit loop positioning.
6.5 Inductive loop alarms
While the boom pole is lowered, this feature allows the following alarms:
• Presence alarm
- Activates an alarm if the closing-loop has been continuously
activated for a predefined time. The alarm will remain activated while the
closing-loop is activated
• Presence time
- The time for which the closing-loop must be continuously
activated before the alarm is activated
• Break-in alarm
- Activates an alarm if the closing-loop is activated while the
boom is lowered. The alarm remains active while the closing-loop is activated,
and for a period of 30 seconds thereafter. This time is fixed
• Alarm output
- This menu item configures the different alarm outputs
Once the required changes are made, exit the menu by pressing the round button.
Menu 7 to Menu 14
Refer to the advanced controller setup for more information (Section 7)
BASIC CONTROLLER SETUP