page 53
www.centsys.com
Buzzer feedback
A warning buzzer will sound (where applicable) as per the table below:
1. The boom pole will close fully and then shut down for two minutes
Inhibitor
name
Priority
Number of beeps
Fault
type
Boom
continues
to
operate
User
can
correct
error
Break-in
alarm
1
Continuous tone for
30 seconds
Alarm
N/A
N/A
Presence
alarm
2
Continuous tone
until ILD is cleared
Alarm
N/A
N/A
Battery low
3
3 beeps periodically
for 30 seconds
Power
system
fault
Yes
1
Yes
Multiple
collision
4
Periodic until
condition is cleared
by user
(500/500ms)
Collision
No
Yes
Auxiliary
overload
5
5 beeps periodically
for 30 seconds
Hardware
No
No
Holiday
Lockout
6
1 beep periodically
for 30 seconds
User
No
Yes
Emergency
stop
7
1 beep periodically
for 30 seconds
User
No
Yes
Time-barring
8
1 beep periodically
for 5 seconds
User
No
Yes
No limits set
9
3 short beeps for 5
seconds
Lost
No
Yes
Mains failure
10
2 beeps periodically
for 30 seconds
Power
system
fault
Yes
Yes
ILD broken
11
1 beep periodically
for 30 seconds
User
No
Yes
DOSS
disconnected
12
5 beeps periodically
for 30 seconds
Hardware
No
No
Fuse blown
13
5 beeps periodically
for 30 seconds
Hardware
No
Yes
Motor
disconnected
14
5 beeps periodically
for 30 seconds
Hardware
No
Yes
Bridge
damaged
15
5 beeps periodically
for 30 seconds
Hardware
No
No
Barrier
stalled
16
4 beeps periodically
for 10 seconds
Collision
No
Yes
TABLE 12
TROUBLESHOOTING
SECTION 9
Summary of Contents for SECTOR II
Page 82: ...page 82 www centsys com Notes...