7.3 REPOSITIONING GEARBOX IN ENCLOSURE
( To convert a factory default orientation 2 to orientation 4 )
The following modifications are done only if it is necessary to change the
orientation of the gearbox inside the enclosure e.g. the unit has been incorrectly
ordered, or site conditions have changed.
Remove M6 x 10
bolts holding
gearbox to enclosure
Remove cables
linking
motor and limit
switch to CP88
control card
Remove bolts
and nuts securing
cross brace to
gearbox assembly
1
2
3
Step
Step
Step
CAPTIVE PLATE
GEARBOX ASSEMBLY
1
Step
CABLE
CONNECTOR
TO CP88
CONTROL
CARD
Step
Cross Bar
3
2
Step