3. Specifications
FIGURE 1. OVERALL DIMENSIONS
Technical specifications
Physical dimensions
Page 7
1167mm
285mm
437mm
304mm
20mm
890mm
Ø76mm
Input voltage
Motor voltage
Motor power supply
Battery charger
Current consumption (mains)
Boom pole length
Boom pole raise time (adjustable)
Manual override
Maximum number of operations per day
Duty cycle - mains present
Operations in standby with 7Ah battery
Half day
Full day
Collision sensing
Operating temperature range
Onboard receiver type
Receiver code storage capacity
Receiver frequency
220-240V AC ± 10%, 50Hz
12V DC
Battery driven (standard capacity - 7Ah)
CP84SM - 2A @ 13.8V
170mA
Allan key operated from outside unit
3000
80%
3000
3000
Electronic
-15°C to +65°C
CENTURION code-hopping multichannel
500 transmitter buttons
433MHz
SECTOR 3
SECTOR 4.5
SECTOR 6
3.0m
1.2 sec
3 sec
3 sec
4.5m
6.0m
Can operate off a solar supply, consult Centurion Systems for assistance
Can increase battery capacity for longer standby times
Boom pole raise and lower times are both individually configurable to suit individual
installation requirements
Based on 25°C ambient temperature and unit not in direct sunlight
Based on an output torque of less than 50% of rated
Based on basic operator excluding closing loop detector Limited by daily usage